Rubber No Rotor Rheometer Rotor-Free Vulcanizer Tester for Rubber Processing Industry Ga-1018-B

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 Year
Still deciding? Get samples of US$ 1000/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (7)
  • Rubber No Rotor Rheometer Rotor-Free Vulcanizer Tester for Rubber Processing Industry Ga-1018-B
  • Rubber No Rotor Rheometer Rotor-Free Vulcanizer Tester for Rubber Processing Industry Ga-1018-B
  • Rubber No Rotor Rheometer Rotor-Free Vulcanizer Tester for Rubber Processing Industry Ga-1018-B
  • Rubber No Rotor Rheometer Rotor-Free Vulcanizer Tester for Rubber Processing Industry Ga-1018-B
  • Rubber No Rotor Rheometer Rotor-Free Vulcanizer Tester for Rubber Processing Industry Ga-1018-B
  • Rubber No Rotor Rheometer Rotor-Free Vulcanizer Tester for Rubber Processing Industry Ga-1018-B
Find Similar Products

Basic Info.

Model NO.
GA-1018-B
Type
Rubber No Rotor Rheometer
Weight
250kg
Transport Package
Plywood Case
Specification
680*630*1100mm
Trademark
GONOAVA
Origin
China
HS Code
9024800000
Production Capacity
200

Product Description

Rubber No Rotor Rheometer Rotor-free Vulcanizer Tester for Rubber Processing Industry GA-1018-B
Overview

The rotor-free vulcanizer is the most widely used instrument in the rubber processing industry to control the quality of rubber, rapid inspection and basic research of rubber. It provides accurate data for the optimized formula combination of rubber, and can accurately determine the parameters such as coke burning time, positive vulcanization time, vulcanization index and maximum and minimum torque.

The vulcanization meter consists of: host, computer, temperature measurement, temperature control, data acquisition and processing, sensor and electrical linkage, etc.The measurement and temperature control circuit is composed of measurement and control module, platinum resistor and heater, which can automatically track the change of power grid and environmental temperature, and automatically correct PID parameters, so as to achieve the purpose of fast and accurate temperature control.The data acquisition system and the electromechanical linkage can automatically detect the moment signal of rubber vulcanization process and automatically display the temperature value and set value in real time.After curing, automatic processing, automatic calculation, printing curing curve and process parameters.Display curing time and curing moment.The computer displays the vulcanization process in real time, from which the change of "temperature" and the change of "time-torque" can be clearly seen.

Technical specifications
The standard of the vulcanization meter is ASTM D5289-95 ISO6502-1999 (E) GB/T16584-1996
Temperature range: room temperature --200ºC
Temperature measurement accuracy: ≤±0.1ºC when 100-200 ºC
Temperature control stability: ≤±0.1ºC at 100-200 ºC
Setting range: 0-200 ºC;Set the minimum unit: 0.1ºC
Temperature display range: 0-200 ºC;Display resolution: 0.1ºC
Set the time range: 0-200 minutes;Set the minimum unit: 1 minute
Automatic range switching: increases automatically according to the actual torque
Power supply: 50HZ, ~ 220V±10%, 50±1Hz, must be well grounded
Compressed air: 0.32mpa controlled by pneumatic control valve
Oscillation frequency: 100 times/min (about 1.7Hz)
Ambient temperature: normal temperature --40ºC, relative humidity less than 80%, no corrosive gases in the air
Material quality: 250 kg
Power: 2 kw
Dimensions: 680×630×1100 (mm)


Machine features
This test instrument has the following characteristics:
A. High precision and wide range of temperature control.(plus or minus 0.1 ºC)
B. Clock programming function.(Setting and modifying time)
C. Technologically advanced switching power supply, wide range of voltage regulation.
D. Imported integrated circuits and control components.
E. English language.
F. Meet the requirements of GB/T16584 (rubber vulcanization characteristics tested with a rotor-free vulcanization meter) and ISO6502.
The powerful microprocessor USES high quality imported chips.For one thing, computers and microprocessors can take signals from torque sensors and record them on graphs.At the same time, the computer and the module interface for data exchange, and control the cavity temperature.
G.The rotor-free vulcanizer was designed with a series of interlocking features, including closing plastic glass doors.If the door is not closed, the mold cannot close.Only when the door is securely closed can the mold be closed.In order to work.
In a word, compared with other models, this type of vulcanizer is more stable in performance, more accurate, cheaper in quality and complete in function.It is the best instrument for testing rubber properties.

Rubber No Rotor Rheometer Rotor-free Vulcanizer Tester for Rubber Processing Industry GA-1018-B
Structure

Rotor-free vulcanizer is an intelligent instrument, which combines the mechanical and electrical principles.It consists of the following parts:
A. Mechanical part: consisting of housing, upper and lower mold, vibrator, force sensor and transmission;
B. Air compressor control system: air compressor is composed of three parts: air cylinder, solenoid valve and air compressor;
C. Electric control system: composed of temperature measurement and control system and door control device;
D. Test and control system: mainly consists of microprocessor, computer control system, data acquisition device, AC device, data processor, motor control, open and close mode control, report printer.The printer is an HP printer and the paper is A4 paper.

Design principle
The mold cavity is composed of upper and lower molds. The rubber sample is placed in an almost airtight mold cavity and maintained at a certain temperature pressure. One of the mold cavities vibrates at a frequency of 1.7Hz, with an amplitude of ±0.5 or ±1.The vibration of the mold cavity causes the sample to produce shear strain, and at the same time, the sample generates a reaction force (torque) to the mold cavity in the opposite direction. The force value depends on the stiffness of the adhesive (shear modulus).
As vulcanization begins, the stiffness of the rubber sample increases, and the reaction force (moment) measured by the force measuring mechanism will gradually rise to the stable value or maximum value and be gradually displayed on the screen. At the same time, a corresponding curve curve of moment and time will be seen, which is usually called "vulcanization curve".The shape of the curve and the test temperature are related to the properties of the binder.After the test, the data and curves will be automatically stored in the database. If you need to print, just click "print".
The shape of the vulcanization curve depends on the temperature being tested and the properties of the rubber sample.In addition to the curves, the computer-controlled printer prints out the corresponding

Rubber No Rotor Rheometer Rotor-free Vulcanizer Tester for Rubber Processing Industry GA-1018-B
Technical parameters.

Data processing technical requirements
Draw the format, curve and parameters as shown in the figure below:
Rubber No Rotor Rheometer Rotor-Free Vulcanizer Tester for Rubber Processing Industry Ga-1018-B

Data on the printed report represents the following:
ML: Minimum torque
MH: Maximum torque
TS1 (early curing time and coke burning time) : ML± 0.1nm, that is, the time corresponding to the increase of 0.1n ·m torque on the basis of ML, calculated in minutes.
TS2 (early curing time and coke burning time) : ML± 0.2nm, that is, the time corresponding to the increase of 0.2n ·m torque on the basis of ML, calculated in minutes.
T10 (initial curing time) : ML+ (MH-ML) ×10% : the time corresponding to the torque reaching this value is calculated in minutes.
T50(vulcanization time that can be accurately assessed) : ML+ (MH-ML) ×50% the time corresponding to the torque reaching this value, calculated in minutes.
T90 (the best curing time often used) : ML+ (MH-ML) ×90% : the time corresponding to the torque reaching this value, calculated in minutes.
VC (vulcanization rate index) : VC=100/ (T90-TS1)

Test Curve:vulcanization curve,Torsion and time coordinate curves
Rubber No Rotor Rheometer Rotor-Free Vulcanizer Tester for Rubber Processing Industry Ga-1018-BRubber No Rotor Rheometer Rotor-Free Vulcanizer Tester for Rubber Processing Industry Ga-1018-BRubber No Rotor Rheometer Rotor-Free Vulcanizer Tester for Rubber Processing Industry Ga-1018-BRubber No Rotor Rheometer Rotor-Free Vulcanizer Tester for Rubber Processing Industry Ga-1018-BRubber No Rotor Rheometer Rotor-Free Vulcanizer Tester for Rubber Processing Industry Ga-1018-BRubber No Rotor Rheometer Rotor-Free Vulcanizer Tester for Rubber Processing Industry Ga-1018-BRubber No Rotor Rheometer Rotor-Free Vulcanizer Tester for Rubber Processing Industry Ga-1018-B