ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device

Hunan Gonoava Instrument Co Ltd
  • Audited Supplier
  • 3 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Dual Sample Testing: Two-bullet design allows parallel testing of two samples simultaneously for efficiency.
  • Fully Automatic Operation: Embedded system handles detection, heating, rotation, and recording without manual intervention.
  • Data Management & Printing: Stores test curves and historical data; supports direct result printing via color touch screen.
  • Standard Compliance: Manufactured according to ASTM D2272 and SH/T0193 standards for accurate evaluation.
  • Customization Available: Product name and specifications can be customized based on customer samples.

Product Images of ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device

ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device pictures & photos
ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device pictures & photos
ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device pictures & photos
ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device pictures & photos
ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device pictures & photos
ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device pictures & photos
ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
  • ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
    ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
  • ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
    ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
  • ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
    ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
  • ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
    ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
  • ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
    ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
  • ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
    ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device

Find Similar Products

Product Description

ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
I. Overview
The automatic lubricating oil oxidation stability tester is designed and manufactured according to the Petrochemical Industry Standard SH/T0193 of the People's Republic of China "Determination of Lubricating Oil Oxidation Stability by Rotating Oxygen Bomb Method" and the American Society for Materials Standard ASTM D2272. This instrument uses an oxygen pressure vessel (oxygen bomb) to evaluate the oxidation stability of new and used turbine oils with the same composition (base oil and additives) at 150°C in the presence of water and copper catalyst.

This instrument can also quickly evaluate the oxidation stability of new mineral insulating oils containing 2,6-di-tert-butyl-p-cresol and (or) 2,6-di-tert-butylphenol antioxidants at 140°C. This instrument is not suitable for measuring mineral insulating oils containing antioxidants with a viscosity greater than 12mm²/s at 40°C.

ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
2. Instrument features:
The automatic lubricating oil oxidation stability tester adopts embedded system design, with automatic detection, automatic rapid temperature rise, automatic recording, and automatic constant speed rotation of the rotating motor during the test. Color touch screen; can store the test curve and results; can view historical data; can print the results on the instrument. After the test starts, the entire test process is completely automatic without human participation, which not only greatly reduces the labor intensity of the operator, but also improves the accuracy of the test results. It is an automated instrument preferred by modern enterprises.

ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device
3. Technical parameters
Power supply AC220V ±10% 50Hz
Pressure sensor range: (0~1.6)MPa, accuracy: 0.5%FS.
Oil bath temperature control point: commonly used 140.0ºC; 150.0ºC.
Temperature control accuracy  ±0.1ºC.
Test form two-bullet design, can do two samples at the same time, convenient for parallel testing.
Rotation speed of the rotating mechanism (100±5)r/min
Angle between the oxygen bomb and the horizontal plane 30°
Oil bath volume about 30L.
Heating tube power 2500

ASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment DeviceASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment DeviceASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment DeviceASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment DeviceASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment DeviceASTM D2272 GA-R0193 Automatic Oxidation Stability Tester Laboratory Oxidation Stability Testing Equipment Device

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASI249867". Items marked "verified" are certified.

Watch Video
Watch Video
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd

About Our Factory & Business Background

verified Business Type
Trading Company
Address
Room 2318, Building 29 Yingyuewan, Runhe Yicheng Yueliangdao Street, Wangcheng, Changsha, Hunan, China
verified Plant Area
120 square meters
verified Number of Employees
8
verified Terms of Payment
T/T, LC, D/P, PayPal, Small-amount payment, Western Union
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port
verified Minimum Order Quantity
1 Piece
verified Supply Chain Partners
9

Our Production Capability & Technical Expertise

verified Main Products
Differential Scanning Calorimeter; Gas Chromatograph; Vacuum Type Dilatometer; Tensile Strength Tester
verified Customization Options
Customization from Samples
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2023-04-06
verified Export Year
1 Year
verified Main Markets
North America, Southeast Asia/ Mideast, East Asia(Japan/ South Korea)
verified Repeat Buyers Choice
< 10%
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
No

Our Certifications, Standards & Industry Recognition

verified Cooperated with Fortune 500
No

FAQ

What standards does this tester comply with?
It is designed and manufactured according to ASTM D2272 and the Chinese Petrochemical Industry Standard SH/T0193.
Can this instrument test both new and used oils?
Yes, it evaluates oxidation stability for new and used turbine oils, as well as new mineral insulating oils with specific antioxidants.
How many samples can be tested at once?
It features a two-bullet design, allowing two samples to be tested simultaneously for parallel testing convenience.
Is the testing process fully automatic?
Yes, the entire process including detection, temperature rise, rotation, and recording is automatic without human participation.
What is the minimum order quantity?
The minimum order quantity is 1 piece.
What payment methods are accepted?
Accepted methods include T/T, LC, D/P, PayPal, Small-amount payment, and Western Union.
What is the lead time for delivery?
The average lead time is within 15 workdays for both peak and off-season periods.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Product Groups