Product Description
UV Irradiation Detector Insulating Glass Ultraviolet Irradiation Detector
1.Product Introduction
The GA-8 Photovoltaic Glass Spectral Transmittance Tester is an instrument designed and manufactured used for testing the transmittance of solar photovoltaic glass. It is also suitable for testing the light transmittance of float glass, insulating glass, tempered glass, laminated glass, coated glass, automotive glass, and other transparent materials.
Equipment introduction
The instrument consists of a worktable, a spectrometer, and a control computer.
- Worktable dimensions: 2000×1300 mm
- Worktable height: 800 mm
- The worktable surface is covered with felt to facilitate smooth sliding of glass.
System features
- Immune to ambient light interference and capable of continuous long-term operation.
- Controlled by an industrial computer, offering excellent scalability and stability.
- The core components of the system feature high stability and durability.
- The system's testing software is user-friendly, with functions including sound prompts, automatic guidance for test paths during automated testing, and the ability to arbitrarily edit the waiting interval time for each test point.
- Test results are automatically stored, and functions for querying, retrieving, statistical analysis, and report printing are highly integrated for convenient use.
Equipment fuctions
- Capable of outputting spectral transmittance values in the 380-1100 nm range and displaying spectral transmittance curves.
- Using the AM1.5 standard solar spectrum and D65 light source spectral distribution, the system can automatically calculate:
- AM1.5 effective integral transmittance
- Visible light transmittance under D65 light source
- Effective transmittance calculated based on user-defined battery response curves
It can also provide transmittance values under other standard light source conditions as required by customers.
- Able to measure the color (Lab*) values and color difference of samples.
- The testing process includes both sound and indicator light prompts:
- A "beep" sounds before testing starts.
- A "boop" sounds after testing ends to remind users not to move the sample during testing.
- The system interface displays indicator lights to show the machine's working status.
- It has an automatic calibration function, the calibration cycle can be set by itself, and the remaining time until the next calibration is displayed in real time.
- There are three working modes: manual testing, automatic testing, and path testing.
6.1 Manual testing mode: After setting parameters such as testing time, testing interval, and number of tests, push the glass into the testing area, manually click "Start Test", and after completing the test, click "Save Results" to save the test data.
6.2 Automatic testing mode: After setting the testing parameters, push the glass into the testing area, and the machine will automatically start testing. After the test is completed, the results will be automatically stored in the database.
6.3 Path testing mode: Edit the number of test points, positions, test order, and time interval between points in advance. After the sample is pushed into the testing area, the screen will prompt the next measurement point according to the planned test path. The measurement path of the test results will be automatically saved after the test is completed.
7. Multiple curves can be superimposed and displayed for comparison of test curves, and the difference curve between two curves can also be provided.
8. All test results are saved in the database, and the data can be retrieved by conditions and exported to EXCEL files.
9. It provides a test data statistics function, generates statistical histograms, and the test results can be printed (if no printer is installed, they can be exported as PDF files).
10. Database data can be exported for storage and backup for permanent preservation.
11. Fault alarm function: When a hardware failure occurs, fault information will be indicated in the screen status bar or pop-up window. The fault information will be stored in the database for analysis.
12. Resistance to ambient light interference.
13. It can operate continuously for a long time.
Product Parameters
UV Irradiation Detector Insulating Glass Ultraviolet Irradiation Detector
2.Product Paramter
Wavelength range |
380-1100nm |
Spectral half-width |
4.3nm |
Wavelength accuracy |
0.2-0.3nm |
Spectral wavelength interval |
≤1nm |
Data storage interval |
1nm,Data calculation interval:5nm |
Measurement speed |
The maximum speed of each measurement at each point 150ms |
Measurement range |
0~100% |
Measurement precision |
0.01% |
Measurement stability |
≤0.05% |
Measurement repeatability |
≤0.05% |
Measurement size |
Maximum: 2400mm×1300mm, minimum: 80mm×80mm |
Measurement geometric conditions |
Integrating sphere illumination, quasi-direct reception |
Integral sphere diameter |
120mm |
Light source specification |
luminaire table 12V20W
|
Light source bulb lifespan |
4000 hours |
Workbench size |
2000mm*1300mm |
Monitor |
31.5 inch |
Overall machine size |
2000mm*1460mm*1100mm (Length * width * height) |
Environmental temperature |
0ºC~40ºC |
Environmental humidity |
<98% |
Power supply method |
Exchange 220V |
Detailed Photos