Lab High Accuracy TCD/FID/FPD/ECD detector gas Chromatograph gcms Gas chromatography Analyzers Mass Spectrometry
Characteristics
Main Specification
| Operation display | vacuum fluorescent display (using agilent technology) |
| Temperature control area | 6 |
| Low operating temperature | room temperature 4 ºC ~ 450 ºC, the incremental 1 ºC |
| Precision | plus or minus 0.1 ºC |
| Program heating order number | 8-16 (optional) |
| Low Cheng Sheng rate | 0.1 ~ 50 ºC / min (ordinary);0.1 ~ 80 ºC / min (high speed) |
| External events | 8 roads;Auxiliary control output 4 |
| Type of sample | filling column, capillary injection sample, six-way valve gas injection, automatic head space sampling |
| Number of detectors | 3 (maximum);(FID, TCD, ECD, FPD, NPD) |
|
|
| (2)Work mode of EPC and EFC: 2 types;Constant current mode, constant pressure mode | |
| Work gas of EPC and EFC | 5 types;Nitrogen, hydrogen, air, helium, argon |
| EPC, EFC cheng sheng | 4 |
| Pressure | 0 ~ 0.6mpa;Flow 0 ~ 100sccm or 0 ~ 500sccm (air) |
| Control accuracy of EPC and EFC | pressure 0.01 KPa;The flow rate of 0.01 SCCM |
| Low pressure sensor | Accuracy:full range of plus or minus 2% reproducibility :< + / - 0.05 KPa |
| temperature coefficient | < + / - 0.01 KPa / ° C range 0 ~ 0.3 MPa or 0 ~ 0.6 MPa; |
| Flow sensor | accuracy full range of < 5% reproducibility:< + 0.5% (full range) range 0 ~ 500sccm(manual, automatic, needle automatic detection) optional |
| Communication interface | Ethernet IEEE802.3 hydrogen flame ionization detector (FID) |
| Detection limit | Mt is less than 3 x 10-12g/s (positive hexadecane - isooctane solution); |
| Baseline noise | less than 5 x 10-14a |
| Baseline drift | no more than 1 x 10-13a /30min |
| Linear range | greater than 106 |
| Highest use low temperature | 450 ºC or less thermal conductivity detector (TCD) |
| The sensitivity | S is greater than 10000mV. Ml/mg (positive hexadecane - isooctane solution) (amplification 1, 2, 4, 8 times optional) |
| Baseline noise | less than 10 mu V |
| Baseline drift | no more than 30 mu v/30min |
| Linear range | > 104 electronic capture detector (ECD) |
| Detection limit | no more than 1 x 10-14g/s (propane hexa6-isooctane solution) |
| Baseline noise | less than 0.03mV |
| Baseline drift | no more than 0.2mv /30min |
| Linear range | greater than or equal to 104 |
| Source | 63Ni flame photometric detector (FPD) |
| Detection limit | (S) less than 5 x 10-11 g/S;(P) is less than or equal to 1 x 10-12g/s (methyl parathion - anhydrous ethanol solution) |
| Baseline noise | less than 0.03mV |
| Baseline drift | no more than 0.2mv /30min |
| Linear range | equal to 103 (S) 102 (P) nitrogen and phosphorus detector (NPD) |
| The detection limit | (N) is less than or equal to 1 times 10-13g/s;(P) less than 5 x 10-14g/s (azobenz-malathion - isooctane solution) |
| Baseline noise | less than 0.03mV |
| Baseline drift | no more than 0.2mv /30min |
| Linear range | greater than or equal to 102 (N) 103 (P) |
Lab High Accuracy TCD/FID/FPD/ECD detector gas Chromatograph gcms Gas chromatography Analyzers Mass Spectrometry