• Lab High Accuracy Tcd/Fid/Fpd/Ecd Detector Gas Chromatograph Gcms Gas Chromatography Analyzers Mass Spectrometry
  • Lab High Accuracy Tcd/Fid/Fpd/Ecd Detector Gas Chromatograph Gcms Gas Chromatography Analyzers Mass Spectrometry
  • Lab High Accuracy Tcd/Fid/Fpd/Ecd Detector Gas Chromatograph Gcms Gas Chromatography Analyzers Mass Spectrometry
  • Lab High Accuracy Tcd/Fid/Fpd/Ecd Detector Gas Chromatograph Gcms Gas Chromatography Analyzers Mass Spectrometry
  • Lab High Accuracy Tcd/Fid/Fpd/Ecd Detector Gas Chromatograph Gcms Gas Chromatography Analyzers Mass Spectrometry

Lab High Accuracy Tcd/Fid/Fpd/Ecd Detector Gas Chromatograph Gcms Gas Chromatography Analyzers Mass Spectrometry

After-sales Service: Online
Warranty: 1 Year
Type: Gas Chromatography Machine
Accuracy Grade: 0.5
Load Way: Electronic Load
Display: Digital
Samples:
US$ 300/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2024

Suppliers with verified business licenses

Hunan, China
Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (6)
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
GA-2903
Weight
0-100Kg
Transport Package
Plywood Case
Trademark
GONOAVA
Origin
China
HS Code
9024800000
Production Capacity
200

Product Description

Product Description

Lab High Accuracy TCD/FID/FPD/ECD detector gas Chromatograph gcms Gas chromatography Analyzers Mass Spectrometry
Characteristics

  1. Using the advanced 10/100m adaptive Ethernet communication interface and built-in IP protocol stack, the instrument can easily realize long-distance data transmission through Intranet and Internet of enterprises;It facilitates the erection of laboratory and simplifies the laboratory configuration and data management.
  2. Low instrument internal design process of three separate connection, can connect to the local processing, unit director and supervisor, you can easily make unit director and supervisor real-time monitoring instrument is running and analysis data;
  3. Low instrument equipped with built-in integration design return control chromatography workstation, get rid of the traditional data acquisition card processing, support up to 253 sets of chromatographic work at the same time, data processing and the chromatograph, reached the domestic leading level;
  4. The Modbus/TCP server built in the built-in integrated return control workstation can easily connect the analysis results to the DCS (distributed control system), and all parameters of the real-time return control chromatograph;
  5. The instrument adopts vacuum fluorescence display technology, high - end atmosphere and convenient interface operation.Have two operating languages in English and Chinese to meet different user needs;
  6. The instrument adopts the modular structure design, the design is clear, the replacement upgrade is convenient, protects the effectiveness of the investment;It can satisfy complex sample analysis, and it can be selected with many high performance detectors, such as FID, TCD, ECD, FPD and NPD.
  7. Can realize completely abandoned the traditional mechanical valve, pointer type pressure gauge mode!EPC technology is used to control gas path and improve the automation level of gas chromatography.
  8. The real gas road failure automatic protection, pressure flow detection automatic ignition, automatic fire extinguishing automatic key, automatic gas path opening, reached a key start;
  9. When the instrument is designed, it can easily complete the online analysis of the gas and liquid sample (with the sample parts).
  10. The system is designed for automatic sampler interface, convenient for automatic sampler and future upgrade.
Product Parameters

Main Specification

Operation display  vacuum fluorescent display (using agilent technology)
Temperature control area  6
Low operating temperature  room temperature 4 ºC ~ 450 ºC, the incremental 1 ºC
Precision  plus or minus 0.1 ºC
Program heating order number  8-16 (optional)
Low Cheng Sheng rate  0.1 ~ 50 ºC / min (ordinary);0.1 ~ 80 ºC / min (high speed)
External events  8 roads;Auxiliary control output 4
Type of sample  filling column, capillary injection sample, six-way valve gas injection, automatic head space sampling
Number of detectors 3 (maximum);(FID, TCD, ECD, FPD, NPD)
  1. it can be controlled by high-precision valve, and the pressure, real-time digital display of the flow and the PC synchronization display are realized.(2) an EPC control system with full back control;
(2)Work mode of EPC and EFC: 2 types;Constant current mode, constant pressure mode
Work gas of EPC and EFC  5 types;Nitrogen, hydrogen, air, helium, argon
EPC, EFC cheng sheng  4
The control range of EPC and EFC:
Pressure  0 ~ 0.6mpa;Flow 0 ~ 100sccm or 0 ~ 500sccm (air)
Control accuracy of EPC and EFC  pressure 0.01 KPa;The flow rate of 0.01 SCCM
Low pressure sensor  Accuracy:full range of plus or minus 2% reproducibility :< + / - 0.05 KPa
temperature coefficient  < + / - 0.01 KPa / ° C range
0 ~ 0.3 MPa or 0 ~ 0.6 MPa;
Flow sensor  accuracy full range of < 5% reproducibility:< + 0.5% (full range) range 0 ~ 500sccm(manual, automatic, needle automatic detection) optional
Communication interface  Ethernet IEEE802.3 hydrogen flame ionization detector (FID)
Detection limit  Mt is less than 3 x 10-12g/s (positive hexadecane - isooctane solution);
Baseline noise  less than 5 x 10-14a
Baseline drift  no more than 1 x 10-13a /30min
Linear range  greater than 106
Highest use low temperature  450 ºC or less thermal conductivity detector (TCD)
The sensitivity  S is greater than 10000mV. Ml/mg (positive hexadecane - isooctane solution) (amplification 1, 2, 4, 8 times optional)
Baseline noise  less than 10 mu V
Baseline drift  no more than 30 mu v/30min
Linear range  > 104 electronic capture detector (ECD)
Detection limit  no more than 1 x 10-14g/s (propane hexa6-isooctane solution)
Baseline noise  less than 0.03mV
Baseline drift  no more than 0.2mv /30min
Linear range  greater than or equal to 104
Source  63Ni flame photometric detector (FPD)
Detection limit  (S) less than 5 x 10-11 g/S;(P) is less than or equal to 1 x 10-12g/s (methyl parathion - anhydrous ethanol solution)
Baseline noise  less than 0.03mV
Baseline drift  no more than 0.2mv /30min
Linear range  equal to 103 (S) 102 (P) nitrogen and phosphorus detector (NPD)
The detection limit  (N) is less than or equal to 1 times 10-13g/s;(P) less than 5 x 10-14g/s (azobenz-malathion - isooctane solution)
Baseline noise  less than 0.03mV
Baseline drift  no more than 0.2mv /30min
Linear range  greater than or equal to 102 (N) 103 (P)
 
Detailed Photos

Lab High Accuracy TCD/FID/FPD/ECD detector gas Chromatograph gcms Gas chromatography Analyzers Mass Spectrometry

Lab High Accuracy Tcd/Fid/Fpd/Ecd Detector Gas Chromatograph Gcms Gas Chromatography Analyzers Mass SpectrometryLab High Accuracy Tcd/Fid/Fpd/Ecd Detector Gas Chromatograph Gcms Gas Chromatography Analyzers Mass SpectrometryLab High Accuracy Tcd/Fid/Fpd/Ecd Detector Gas Chromatograph Gcms Gas Chromatography Analyzers Mass SpectrometryLab High Accuracy Tcd/Fid/Fpd/Ecd Detector Gas Chromatograph Gcms Gas Chromatography Analyzers Mass SpectrometryLab High Accuracy Tcd/Fid/Fpd/Ecd Detector Gas Chromatograph Gcms Gas Chromatography Analyzers Mass Spectrometry
 

Send your message to this supplier