Open And Close Porosity Analyzer True Density Analyzer Product details
1.Full constant temperature test system
Constant temperature is a necessary condition to obtain accurate and reliable data. Due to the nature of gas expansion and contraction, the change of temperature will directly affect the accuracy of gas quantification technology. Piord has developed and obtained full constant temperature technology, using advanced wind and heat circulation device, built-in multi-point intelligent temperature control terminal, to achieve full constant temperature of the entire test system, constant temperature control accuracy can reach 0.01ºC. The application of the system can effectively improve the accuracy and repeatability of the data, avoid the direct blowing of the air conditioner, the ventilation of the window, and the influence of the ambient temperature difference on the measurement accuracy and repeatability of the instrument.
2.Accurate volumetric measurement system
The volume of a general solid material can be calculated by measuring its length, width and height. However, most solid surfaces are irregular and have holes or cracks of varying sizes. The solid itself has open holes, through holes and closed holes, and its volume (that is, skeleton volume) cannot be accurately obtained by traditional methods. The essence of gas densitometry instrument is to measure volume, the test system in addition to the constant temperature system, but also need to have an accurate quantitative system. Piaud Instruments use accurately calibrated double quantifiers, multi-structure sealed tanks, and superior vacuum technology to protect the testing of solid materials.
3.Simple and clear operation interface
TD series true density analyzer gets rid of computer control, and the host is embedded with a more stable WINDOWS CE industrial control system, providing users with a simple and clear operation interface. One-click startup, automatic testing and data storage, built-in storage space for at least 2 million test reports. View and retrieve past data at any time, reserve USB interface, export and print immediately.
4.Scientifically rigorous equipment calibration
The calibration of TD-1100 true density meter is carried out in three ways: 1. Measuring the empty bin volume and repeating the test for more than 10 times to ensure the volume repeatability deviation < 10 microliters; 2, the test has been strictly measured stainless steel standard body, repeated testing more than 10 times, to ensure that the equipment test volume value and standard value deviation < 10 microliters; 3, provide coal standard samples to ensure that the density value is within the specified range. (There are commercially available methods of using density values or simply using the volume value of the metal for calibration, which are not reasonable. The true density instrument is actually a volume measuring instrument, and it is unreasonable to calibrate the instrument with density value. The uncertainty range of the volume value of the metal is large, which can not meet the use requirements of the gas true density meter.
Open And Close Porosity Analyzer True Density Analyzer Basic parameter
Test method: Two test methods are provided, static vacuum gas displacement method and gas expansion method (injection pressure method).
Model basis: Boyle-Malott law [Quantitative gas in a closed container, at constant temperature, gas pressure and volume are inversely proportional, the mathematical formula is: pV=C (constant)] Accurate measurement of the volume of the sample to be measured
Full constant temperature system: full constant temperature technology, the temperature variable of the test system is not greater than ±0.01ºC, and is not affected by the ambient temperature of use
Vacuum system: vacuum system and vacuum pump, vacuum static extraction technology; The flexible setting of the vacuum balance time can effectively remove the moisture adsorbed on the sample surface and the air diffused into the sample pool, making the quantification more accurate
Vacuum balance time: it can be flexibly set according to the actual situation of the sample, which can remove the moisture and gas adsorbed on the surface of the sample, so that the quantitative is more accurate
Analysis station: 1 analysis station, sample pool volume 20cm3; There are also 50/100/200cm3 and ultra-small volume sample pools available for customization
Test accuracy: better than ±0.02%, repeatability is excellent ±0.02%, resolution 0.0001g/cm3
Test duration: 6 minutes
Control system: high resolution LCD touch screen, embedded in WINDOWS CE industrial control system, fast processing speed, stable performance, no external computer required for testing; Interfaces such as R232 and Ethernet are configured for easy interconnection with other systems
Pressure detection system: imported pressure sensor
Gas path control system: Advanced I-PID variable dynamic regulation technology to improve vacuum efficiency and prevent sample spatter
Multi-structure sample pool seal: Sample pool adopts advanced mechanical seal structure (special tool operation to ensure cabin body tightness and operational reliability)
Micro test: quantitative manifold switching system to achieve accurate analysis of very small samples
Data calibration: Intelligent automatic calibration
Data acquisition system: high precision 24-bit analog-to-digital conversion system, with instrument unexpected power failure data storage function
Other functions: Open/closed rate test (GB/T10799-2008)
Specifications: Length 400mm, width 580mm, height 310mm; Power 500W; Working voltage 220V
Open And Close Porosity Analyzer True Density Analyzer