ASTM D971automatic Surface Tension Meter /Measurement Machine with Platinum Ring Method

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 Year
Still deciding? Get samples of US$ 300/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (7)
  • ASTM D971automatic Surface Tension Meter /Measurement Machine with Platinum Ring Method
  • ASTM D971automatic Surface Tension Meter /Measurement Machine with Platinum Ring Method
  • ASTM D971automatic Surface Tension Meter /Measurement Machine with Platinum Ring Method
  • ASTM D971automatic Surface Tension Meter /Measurement Machine with Platinum Ring Method
  • ASTM D971automatic Surface Tension Meter /Measurement Machine with Platinum Ring Method
  • ASTM D971automatic Surface Tension Meter /Measurement Machine with Platinum Ring Method
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
Overview

Basic Info.

Model NO.
GA-Q2000
Mass Scope of Workpiece
<900kg
Type
Automatic Surface Tension Meter
Accuracy Grade
0-2000mn/M
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
18kg
Power Source
110V Or220V,50W
Transport Package
Plywood Case
Specification
300 × 300 × 450mm
Trademark
GONOAVA
Origin
China
HS Code
9024800000
Production Capacity
200

Product Description

Product Description

ASTM D971 DIN EN 14210 Automatic Surface Tension Meter surface tension measurement machine with platinum ring method
1.
Test Standards

ASTM D971 -- Standard Test method for Determination of interfacial tension between oil and water by the Lifting Ring Method
ASTM D1331-- Standard Test method for Surface and Interfacial tension in surfactant Solutions
ASTM D1417 -- Standard Method for Testing synthetic rubber latex
DIN EN 14210-- Surfactants -- Determination of interfacial tension of surfactant solutions by stirrup or suspension ring method
DIN EN 14370 -- Surfactants -- Determination of surface tension
ISO 304-- Surfactants -- Determination of surface tension by the pull film method
ISO 1409 -- Plastics/rubber -- Polymer dispersions and rubber latex (natural and synthetic) -- Determination of surface tension by the ring method
OECD 115-- OECD guide for testing chemicals: Surface tension in aqueous solutions
ISO 6889 -- Surfactant -- Determination of surface tension by the pull film method

ASTM D971 DIN EN 14210 Automatic Surface Tension Meter surface tension measurement machine with platinum ring method
2.Introduction

Physical science defines surface tension as shrinking and minimizing the surface area of a liquid. If the surface is enlarged by the formation of a liquid sheet, it means that the surface/interfacial tension is exerted by a measurable tensile force when the test body (such as a Wilhelmy plate or a Du Nouy ring) is in contact with the liquid. Inside the machine, this force is measured by a high-precision load cell system, so the surface/interfacial tension of the liquid can be calculated.
Using a tensiometer, it is also possible to measure the interfacial tension between two liquids when the test bodies are not melted. Because tensimetry is based on force measurements, in contrast to optical analysis of pendant droplets, there is no requirement that one of the liquids be transparent or that the refractive index differs between the two liquids. Therefore, tensimetry is a convenient alternative to optical measurements of surface and interfacial tension in many cases.

ASTM D971 DIN EN 14210 Automatic Surface Tension Meter surface tension measurement machine with platinum ring method
3.Application field

★ The effectiveness and efficiency of surfactants were evaluated by measuring critical micelle concentration
★ Wettability of tablets, pharmaceutical active ingredients and excipients
★ Wettability of paint and coatings
Oil aging degree detection
★ Coating wettability and adhesion
★ Cosmetic development
★ Study on ink wetting characteristics

ASTM D971 DIN EN 14210 Automatic Surface Tension Meter surface tension measurement machine with platinum ring method
4.Surfactant CMC Measurement

Surface-active compounds such as surfactants consist of a hydrophilic part and a hydrophobic part, so they preferably adsorb at the interface. They reduce the surface or interfacial tension, respectively, which is crucial for good washing performance or foam stability.There is a limit to the number of surfactant molecules that can be accommodated on a given surface area. The only possibility for "excess" surfactant molecules to protect their hydrophobic moieties from water is to form micelles. The specific surfactant concentration reached to initiate micelle formation is called the "critical micelle concentration" (CMC). This can be easily determined by varying the measurement of surfactant concentration: below the CMC, the surface tension decreases with increasing concentration as more and more surfactant molecules are adsorbed on the surface. Above the CMC basis, further added surfactants are only used to form micelles and the surface tension remains constant.


ASTM D971 DIN EN 14210 Automatic Surface Tension Meter surface tension measurement machine with platinum ring method
5.Wetting phenomenon

Using tensimetry, the wettability and dynamic contact angle of solid samples used as test bodies can also be investigated. Therefore, the sample is immersed in a liquid with known surface tension and pulled out again. In this case, the weighing system detects the buoyancy and sheet weight in real time. During evaluation, buoyancy effects can be removed from the data so that the advancing angle of immersion and the receding angle of withdrawal can be determined according to the Wilhelmy equation.

ASTM D971 DIN EN 14210 Automatic Surface Tension Meter surface tension measurement machine with platinum ring method
6.Wilhelmy Plate method

The Wilhelmy plate method is a well-established method for determining surface and interfacial tension using tensiometers. This method uses a Wilhelmy plate as a test body. It is usually made of platinum iridium and is only a few centimeters in length and height. The plate is connected to the weighing system of the tensiometer and is positioned on the surface of the liquid in such a way as to form a sheet of the liquid. The force on the sheet is measured, which is equal to the vertical part of the tension caused by the surface tension. Together with defining surface tension as the tension on each side of the contact line length, this yields the Wilhelmy equation.
All Design Features Are Developed For Your Exact Needs

ASTM D971 DIN EN 14210 Automatic Surface Tension Meter surface tension measurement machine with platinum ring method
7.Product
 Feature 

1.High quality core components ensure accurate measurement, each tensimeter is equipped with a high-precision mechanical electromagnetic force sensor, the highest precision of surface tension up to 0.001 mN/m.
2.Tensimeter adopts 7 inch touch screen, all information is clearly displayed on the screen and the operation is completed.The machine does not need a computer when operating, can be used, support Chinese and English exchange display.
3.A tractor serves several purposes.
The tensimeter can meet the plate/ring method measurement, data direct reading does not need to calculate, plate/ring design size and process meet domestic/foreign standards.
4.Liquid density measurement
According to the buoyancy principle, the density of the tested sample can be accurately obtained by immerging the standard volume part in the test sample.
5.Measurement space with LED lighting
The lighting device in the spacious measurement area can illuminate the sample surface and the measuring body, so that the sample positioning is more accurate.
6.A wealth of optional accessories
Provide a variety of accessories to meet often different test needs.



ASTM D971 DIN EN 14210 Automatic Surface Tension Meter surface tension measurement machine with platinum ring method
8.Measurement methods

★ Q series tensiometers provide a variety of measurement methods, including the traditional platinum plate method (Wilhelmy) and platinum ring method (DuNouy), as well as optional density accessories to accurately measure the density of the sample under test.
★ Platinum ring method can be set one stretch or multiple stretches, can be set by yourself.No calculation, automatic measurement.
Built-in electronic level, with operating instructions.It can accurately adjust the level of the sample table to ensure the accurate measurement of the tensimeter.
★ The spacious sample room is equipped with transparent glass sliding door, which is very convenient to operate and can prevent the influence of indoor air flow on stability measurement.
★ The built-in measuring program can control the lifting of the sample platform to ensure no human interference in the measuring process. The running speed can be adjusted according to the requirements of the experiment and can be repeated accurately.The use of dynamic and fluid actuation eliminates vibrations that can have negative effects.
★ Electromagnetic force sensor and matching control system, temperature compensation function, can reduce long-term drift to a minimum.
★ Simple and intuitive operation through 7-inch touch screen.Intuitive operation on the touch screen is a major feature of the new generation of tensimeter, no matter before or during the measurement, can easily control the sample table and other components.
Built-in measurement data management menu, easy to view data and support external printer operation.All measurement data files can be transferred through THE U disk and converted into Excel files for convenient management, recording and sorting of measurement data.

ASTM D971 DIN EN 14210 Automatic Surface Tension Meter surface tension measurement machine with platinum ring method
9.Measurement and data management software ST Flash

Q series tensimeter software has clear user guidance, operation is very convenient.Our ST Flash software supports simple data management, CMC analysis and calculation through easy-to-understand charts, comprehensive measurement reports and data organization functions.
★ Support data collection, and can annotate the data, easy to view comparison.
★ The collected data is saved in the form of TXT document for easy viewing and conversion, and printed in THE form of PDF to generate graphic documents.
★ A maximum of eight groups of data can be compared simultaneously.
★ The ST Flash software provides the TOOL package for analyzing CMC concentration.
★ Software support Chinese and English operation and display

Product Parameters

ASTM D971 DIN EN 14210 Automatic Surface Tension Meter surface tension measurement machine with platinum ring method
10.Detailed technical parameters

Model Q2000 Q1000 Q500
Test method* Platinum plate method, platinum ring method
Surface tension test range 0-2000mN/m 0-1000mN/m 0-500mN/m
Accuracy of surface tension 0.1mN/m 0.01mN/m 0.001mN/m
Liquid density range 0-3.000g/cm3 N/A
Density accuracy 0.001g/cm3 N/A
Operating mode Automatic lifting and automatic measurement of sample table
Lifting speed 0-300mm/min  can be adjusted arbitrarily
Display mode 7 inch touch screen data direct reading
Data mode Supports data storage, viewing, and printing
Measuring time Routine within 60 seconds
Data output RS232(printer) or USB
Data software
 
ST Flash software is standard
Dimension 47*24.5*47.5 cm Length * width * height
Net weight 18kg
Power supply 110V or220V,50W
Ring size: wire radius is 0.185mm, ring radius is 9.55mm, ring circumference is 60mm,
N/A: means that this function is not included.
*Note: The board/ring test method needs to be specified when ordering. Choose one of the two standard configurations. If the budget is sufficient, it is recommended to configure both the board and the ring.
**Note: The standard configuration of the printer is not included, it can be purchased separately according to the needs, and the standard volume parts must be purchased separately for measuring the liquid density.
 
Detailed Photos




ASTM D971automatic Surface Tension Meter /Measurement Machine with Platinum Ring Method

Company Profile

ASTM D971automatic Surface Tension Meter /Measurement Machine with Platinum Ring Method

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier