Ga-P10d Integrated Ion Chromatograph Single System Ion Chromatograph Analyzer Anion Cationic Tester

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 Year
Still deciding? Get samples of US$ 10000/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (7)
  • Ga-P10d Integrated Ion Chromatograph Single System Ion Chromatograph Analyzer Anion Cationic Tester
  • Ga-P10d Integrated Ion Chromatograph Single System Ion Chromatograph Analyzer Anion Cationic Tester
  • Ga-P10d Integrated Ion Chromatograph Single System Ion Chromatograph Analyzer Anion Cationic Tester
  • Ga-P10d Integrated Ion Chromatograph Single System Ion Chromatograph Analyzer Anion Cationic Tester
  • Ga-P10d Integrated Ion Chromatograph Single System Ion Chromatograph Analyzer Anion Cationic Tester
  • Ga-P10d Integrated Ion Chromatograph Single System Ion Chromatograph Analyzer Anion Cationic Tester
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
GA-P10D
Display
Digital
Weight
0-100Kg
Power Source
AC220V
Temperature
2mm±0.05mm (6 PCS) 10~30ºC
Humidity
25~85%
Transport Package
Plywood Case
Trademark
GONOAVA
Origin
China
HS Code
9024800000
Production Capacity
200

Product Description

Product Description
GA-P10D integrated ion chromatograph Single system ion chromatograph Analyzer Anion cationic tester
1.Description
GA-P10D Fully automatic ion chromatograph (Flexible configuration of single system/dual system/Fully automatic/integrated ion chromatograph)

2.Performance characteristics
Flexible configuration of the integrated model, saving time, labor, land, efficient
Effectively overcome the project interference before the dual system, can achieve double conductivity detector, double high-pressure infusion pump, double sampling valve (manual or electric), double separation, dual channel workstation integration, one machine top two use, sample detection more, fast, good, save, high efficiency.
2. A multi-purpose machine, superior function, accurate detection
It can realize the simultaneous detection of anions and ions in two systems. Gradient leaching can be performed to detect organic acids; It can be equipped with voltammetry (amperage) detector to complete the detection of anions such as bromine, iodine, sulfur, cyanogen, cations such as lead, copper, zinc, cadmium and organic matter; With a variety of forms of column valve switching device, can be used with a variety of chromatographic columns (ion exclusion column, liquid chromatography column, ion chromatography column) for the separation and determination of a variety of substances.
3. Sampling system
With Qingdao Puren PAS series automatic sampler to realize automatic sampling, no manual duty, multi-sample continuous analysis.
4. The PIC series dual system ion chromatograph passed the verification of the Chinese Academy of Metrology Science in 2007, and obtained the dual system test certificate.
5. Domestic good instruments
After expert preliminary review and user research, weight scoring, PIC-10A type ion chromatograph &PAS type automatic sampler two products were selected as "domestic good instrument".
 
Product Parameters
GA-P10D integrated ion chromatograph Single system ion chromatograph Analyzer Anion cationic tester
3. Main Technical Parameters
1. Equipment use: canalization and anion analysis in samples
2. Configuration requirements
★2.1 Built-in pool column integrated constant temperature system [provide qualification documents] 1 set
2.2 One conductivity detector
2.3 1 set of high-pressure advection pump
2.4 One set of six-way sampling valves
2.5 One set of flow system
2.6 One anion separation column
2.7 One set of anion suppressor
2.8 One set of chromatographic workstations
2.9 1 set of accessories
3. Technical parameters
3.1 High pressure advection pump:
The microprocessor-controlled double-plunger reciprocating pump adopts advanced intelligent control algorithm, which can reduce the flow pulsation of the pump to the lowest level.
★3.1.1 Pressure test: ≥36MPa (JJG823-2014 "Ion Chromatograph Metrology Verification Regulations" shall prevail, and provide the type evaluation report and type approval certificate of measuring instruments issued in accordance with this regulation)
★3.1.2 Maximum pressure: 42MPa (provide measurement reports issued by provincial and above measurement departments)
★3.1.2 Flow range: 0.001ml/min ~ 15.000ml/min (provide measurement reports issued by provincial and above measurement departments)
3.1.3 Pressure sensor: pressure display accuracy ≤0.1MPa
3.1.4 Overpressure protection: When the working pressure exceeds or is lower than the set upper or lower limit, the pump will shut down and alarm.
3.2 Conductivity detector:
3.2.1 Pool volume: < 0.8ul.
3.2.2 Operating pressure: 10Mpa.
★3.2.3 Conductivity detection range: 0-60000uS, 1-8 adjustable, with manual and automatic file selection function. (Provide measurement reports issued by provincial and above measurement departments)
★3.2.4 Full range detection resolution: ≤0.0010ns/cm (provide measurement reports issued by provincial and above measurement departments)
3.3 Anion suppressor:
3.3.1 Continuous automatic regeneration electrochemical microfilm suppressor, online automatic regeneration, high inhibition capacity, low background conductance, low noise, baseline stability, maintenance-free.
3.3.2 Anti-pollution, good pressure resistance, long life, wide range of use (PH0-14).
3.3.3 Small size, fast stabilization time, stabilization time is not more than 12 minutes, and good reproducibility.
3.4 Flow path system:
3.4.1 The flow path system is made of PEEK material (imported parts), which has good versatility and can use strong acid and alkali eluent.
3.4.2 Compatible with 100% organic solvents, it is convenient for users to analyze, rinse and maintain complex samples.
3.5 Chromatographic Workstation:
3.5.1 24-bit high-precision and high-sensitivity digital-to-analog conversion.
3.5.2 Dedicated ion chromatographic workstation, full Chinese display, digital signal transmission with computer through high-performance USB, to complete cationic data acquisition and processing.
3.5.3 Instrument counter-control operation can be realized, instrument working parameters can be set online through the computer, and man-machine dialogue can be conducted.
3.5.4 Automatically receive analysis and control preservation instrument chromatographic conditions.
3.5.5 Automatic negative peak identification and baseline deduction function. Automatic parameter integration, automatic report generation.
3.5.6 Automatically detect the running status of the instrument, give an alarm to the running fault and provide protective measures for the instrument.
3.6 Test technical indicators: (JJG823-2014 "Ion Chromatograph Metrology Verification Regulations" shall prevail, and provide the type evaluation report and type approval certificate of measuring instruments issued in accordance with this regulation)
Anions: Seven anions such as F-, Br-, Cl-, SO42-, NO3-, NO2- and HPO42- can be analyzed in one sample
★3.6.1 Minimum detection limit: (provide measurement reports issued by provincial and above measurement departments)
★ 3.6.1.1Cl -≤0.0001μg/mL
★3.6.1.2 Li+≤0.0001μg/mL
3.6.2 Linear correlation coefficient ≥0.999
★3.6.3 Linear range: ≥103(in Cl-)
★3.6.4 Baseline noise: 0.0003μS/cm (provide measurement reports issued by provincial and above metrology departments)
★3.6.5 Baseline drift: 0.003μS/30min (Provide measurement reports issued by provincial and above metrology departments)
★3.6.6 Qualitative repeatability: ≤0.02% (provide measurement reports issued by provincial and above measurement departments)
★3.6.7 Quantitative repeatability: ≤0.2% (provide measurement reports issued by provincial and above measurement departments)
★3.6.8 Column temperature box temperature stability: ≤0.1ºC/h
4. Performance indicators:
(1) The instrument operating system is completed by one click of the mouse, with automatic selection of range, automatic zero setting, current setting and other functions.
(2) In the large-screen program of the instrument, there is a small workstation to display spectrogram processing data and save spectrogram data.
5, the instrument working environment:
Voltage: AC220V±10% 50HZ
Temperature: 10~30ºC
Humidity: 25~85%

4.Product configuration list
Number Device name Specifications and models
1 ion chromatograph GA-P10D Model
2 Automatic sampler (optional) PAS-1 type (50 bits)
Number name of parts Quantity
1 Ion chromatograph mainframe 1 Piece
2 Column box and constant temperature system 1 Piece
3 electrical conductivity detector 1 Piece
4 High pressure advection pump 1 Set
5 Six access sample valve 1 Set
6 Flow pipe fitting 1 Set
7 Anion separation column 1 Piece
8 Anion automatic regeneration suppressor 1 Set
9 chromatographic work station 1 Set
10 Attached accessories (anti-control work software) 1 Set
Spare parts and special tools are included
equipment type
 
Number Name specifications and models
 
Origin Quantity
spare part
 
1 PEEK High pressure flow pipe φ1.5×0.5 America
 
1 meter
2 tetrafluoroduct φ1.5×0.5 domestic
 
5 meter
3 High pressure column joint -- America
 
10 Pieces
4 Pretreatment column -- domestic
 
2 Pieces
5 Einwegfilter -- domestic 2 Pieces
special tools
 
1 Analog electrical guide board -- Prem Rawat 1 Piece
2 resistance
 
100Ω/2W domestic
 
1 Piece
3 Syringe (automatic none) 2ml domestic
 
2 Pieces
4 hex key No.3 domestic
 
1 Piece
5 cross head screw-driver
 
5*100 domestic
 
1 Piece
6 Inch wrench 1/4 domestic
 
1 Piece
7 mouse
 
-- domestic
 
1 Piece

Some national/industry testing standards
Standard number Standard name
HJ 1050-2019  Water quality - Determination of chlorate, chlorite, bromate, dichloroacetic acid and trichloroacetic acid - ion chromatography
HJ 1041-2019 Determination of trimethylamine in the exhaust gas of stationary sources by suppressed ion chromatography
HJ 1040-2019 Determination of hydrogen bromide in waste gas from stationary sources - ion chromatography
HJ 1004-2018 Determination of organic acids (acetic acid, formic acid and oxalic acid) in ambient air precipitation by ion chromatography
HJ1005-2018 Determination of cations (Na+, NH4+, K+, Mg2+, Ca2+) in ambient air precipitation by ion chromatography
HJ 800-2016 Water-soluble cations in ambient air particles (Li+, Na+, NH4+, K+)
HJ 84-2016 Water quality determination of inorganic anions (F-, Cl-, NO2-, Br-, NO3-, PO43-, SO32-, SO42-)
HJ 812-2016 Water quality determination of soluble cations (Li+, Na+, NH4+, K+, Ca2+, Mg2+) by ion chromatography
HJ 549-2016 Determination of hydrogen chloride in ambient air and exhaust gas - ion chromatography
HJ 799-2016 Water-soluble anions in ambient air particles (F-, Cl-, Br-, NO2-, etc.)
HJ 669-2013 Water quality - Determination of phosphate - ion chromatography
HJ 544-2016 Determination of sulfuric acid fog in the exhaust gas of stationary sources - ion chromatography
HJ 778-2015 Water quality - Determination of iodide - ion chromatography
HJ 779-2015 Determination of hexavalent chromium in ambient air by post column derived ion chromatography
HJ/T 83-2001 Water quality determination of adsorbable organic halogens (AOX) by ion chromatography
HJ 769-2015 Determination of total sulfur in coal -- Escard-ion chromatography
HJ 800-2016 Determination of total sulfur in coal -- Escard-ion chromatography
HJ 84-2016 Water quality determination of inorganic anions (F-, Cl-, NO2-, Br-, NO3-, PO43-, SO32-, SO42-)
GB 5009.245-2016 Determination of polyglucose in food of national safety
GB 5009.258-2016 Determination of raffinose in food of national safety
GB 5009.256-2016 Determination of multiple phosphates in food for national safety
GB 5009.255-2016 Determination of fructan in food of national safety
GB 5009.33-2016 National safety of food - Determination of nitrite and nitrate in food
GB 8538-2016 National standard for food safety test method for drinking natural mineral water
GB/T 5750.5-2006 Standard test methods for drinking water Inorganic nonmetallic indicators
GB/T 5750.10-2006 Standard test methods for drinking water Index of disinfection by-products
GB/T 5750.6-2006 Standard test method for drinking water Metal index
GB/T 31197-2014 Determination of impurity anions in inorganic chemical products-ion chromatography
GB/T 30906-2014 Determination of sodium tripolyphosphate in sodium tripolyphosphate by ion chromatography
GB/T 11446.7-2013 Determination of trace anions in electronic grade water by ion chromatography
GB/T 29400-2012 Determination of trace anions in chemical fertilizers by ion chromatography
GB/T 3884.12-2010 Methods for chemical analysis of copper concentrates - Part 12: Determination of fluorine and chlorine content - ion chromatography
GB/T 6730.69-2010 Methods for chemical analysis of copper concentrates - Part 12: Determination of fluorine and chlorine content - ion chromatography
GB/T 24876-2010 Determination of seven anions in livestock and poultry breeding wastewater by ion chromatography
GB/T 23978-2009 Liquid dyes - Determination of chloride ion content - ion chromatography
GB/T 14642-2009 Industrial circulating cooling water and boiler water fluorine, chlorine, phosphoric acid, nitrite, nitric acid and sulfur
GB/T 15454-2009 Determination of sodium, ammonium, potassium, magnesium and calcium ions in industrial circulating cooling water - Ion chromatography
GB/T 23710-2009 Determination of sodium, ammonium, potassium, magnesium and calcium ions in industrial circulating cooling water - Ion chromatography
GB/T 21533-2008 Determination of starch syrups in honey by ion chromatography
GB/T 20188-2006 Determination of bromate in wheat flour by ion chromatography
GB/T 13580.5-1992 Determination of Fluorine, chlorine, nitrite, nitrate and sulfate in atmospheric precipitation by ion chromatography
GB/T 32953-2016 Determination of melamine content in fertilizer by ion chromatography
GB/T 11733-1989 Standard method for hygienic inspection of sulphates in the atmosphere of residential areas - ion chromatography
 
Detailed Photos

Ga-P10d Integrated Ion Chromatograph Single System Ion Chromatograph Analyzer Anion Cationic Tester
Ga-P10d Integrated Ion Chromatograph Single System Ion Chromatograph Analyzer Anion Cationic Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier