Customization: | Available |
---|---|
After-sales Service: | Online |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 4000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Single system ion chromatograph Analyzer Laboratory Chromatography Testing Machine Anion cationic tester For water quality environment mineral fertilizer
Product Introduction:Number | Device name | Specifications and models |
1 | ion chromatograph | GA-P10D Model |
2 | Automatic sampler (optional) | PAS-1 type (50 bits) |
Number | name of parts | Quantity |
1 | Ion chromatograph mainframe | 1 Piece |
2 | Column box and constant temperature system | 1 Piece |
3 | electrical conductivity detector | 1 Piece |
4 | High pressure advection pump | 1 Set |
5 | Six access sample valve | 1 Set |
6 | Flow pipe fitting | 1 Set |
7 | Anion separation column | 1 Piece |
8 | Anion automatic regeneration suppressor | 1 Set |
9 | chromatographic work station | 1 Set |
10 | Attached accessories (anti-control work software) | 1 Set |
equipment type |
Number | Name | specifications and models |
Origin | Quantity |
spare part |
1 | PEEK High pressure flow pipe | φ1.5×0.5 | America |
1 meter |
2 | tetrafluoroduct | φ1.5×0.5 | domestic |
5 meter | |
3 | High pressure column joint | -- | America |
10 Pieces | |
4 | Pretreatment column | -- | domestic |
2 Pieces | |
5 | Einwegfilter | -- | domestic | 2 Pieces | |
special tools |
1 | Analog electrical guide board | -- | Prem Rawat | 1 Piece |
2 | resistance |
100Ω/2W | domestic |
1 Piece | |
3 | Syringe (automatic none) | 2ml | domestic |
2 Pieces | |
4 | hex key | No.3 | domestic |
1 Piece | |
5 | cross head screw-driver |
5*100 | domestic |
1 Piece | |
6 | Inch wrench | 1/4 | domestic |
1 Piece | |
7 | mouse |
-- | domestic |
1 Piece |
Standard number | Standard name |
HJ 1050-2019 | Water quality - Determination of chlorate, chlorite, bromate, dichloroacetic acid and trichloroacetic acid - ion chromatography |
HJ 1041-2019 | Determination of trimethylamine in the exhaust gas of stationary sources by suppressed ion chromatography |
HJ 1040-2019 | Determination of hydrogen bromide in waste gas from stationary sources - ion chromatography |
HJ 1004-2018 | Determination of organic acids (acetic acid, formic acid and oxalic acid) in ambient air precipitation by ion chromatography |
HJ1005-2018 | Determination of cations (Na+, NH4+, K+, Mg2+, Ca2+) in ambient air precipitation by ion chromatography |
HJ 800-2016 | Water-soluble cations in ambient air particles (Li+, Na+, NH4+, K+) |
HJ 84-2016 | Water quality determination of inorganic anions (F-, Cl-, NO2-, Br-, NO3-, PO43-, SO32-, SO42-) |
HJ 812-2016 | Water quality determination of soluble cations (Li+, Na+, NH4+, K+, Ca2+, Mg2+) by ion chromatography |
HJ 549-2016 | Determination of hydrogen chloride in ambient air and exhaust gas - ion chromatography |
HJ 799-2016 | Water-soluble anions in ambient air particles (F-, Cl-, Br-, NO2-, etc.) |
HJ 669-2013 | Water quality - Determination of phosphate - ion chromatography |
HJ 544-2016 | Determination of sulfuric acid fog in the exhaust gas of stationary sources - ion chromatography |
HJ 778-2015 | Water quality - Determination of iodide - ion chromatography |
HJ 779-2015 | Determination of hexavalent chromium in ambient air by post column derived ion chromatography |
HJ/T 83-2001 | Water quality determination of adsorbable organic halogens (AOX) by ion chromatography |
HJ 769-2015 | Determination of total sulfur in coal -- Escard-ion chromatography |
HJ 800-2016 | Determination of total sulfur in coal -- Escard-ion chromatography |
HJ 84-2016 | Water quality determination of inorganic anions (F-, Cl-, NO2-, Br-, NO3-, PO43-, SO32-, SO42-) |
GB 5009.245-2016 | Determination of polyglucose in food of national safety |
GB 5009.258-2016 | Determination of raffinose in food of national safety |
GB 5009.256-2016 | Determination of multiple phosphates in food for national safety |
GB 5009.255-2016 | Determination of fructan in food of national safety |
GB 5009.33-2016 | National safety of food - Determination of nitrite and nitrate in food |
GB 8538-2016 | National standard for food safety test method for drinking natural mineral water |
GB/T 5750.5-2006 | Standard test methods for drinking water Inorganic nonmetallic indicators |
GB/T 5750.10-2006 | Standard test methods for drinking water Index of disinfection by-products |
GB/T 5750.6-2006 | Standard test method for drinking water Metal index |
GB/T 31197-2014 | Determination of impurity anions in inorganic chemical products-ion chromatography |
GB/T 30906-2014 | Determination of sodium tripolyphosphate in sodium tripolyphosphate by ion chromatography |
GB/T 11446.7-2013 | Determination of trace anions in electronic grade water by ion chromatography |
GB/T 29400-2012 | Determination of trace anions in chemical fertilizers by ion chromatography |
GB/T 3884.12-2010 | Methods for chemical analysis of copper concentrates - Part 12: Determination of fluorine and chlorine content - ion chromatography |
GB/T 6730.69-2010 | Methods for chemical analysis of copper concentrates - Part 12: Determination of fluorine and chlorine content - ion chromatography |
GB/T 24876-2010 | Determination of seven anions in livestock and poultry breeding wastewater by ion chromatography |
GB/T 23978-2009 | Liquid dyes - Determination of chloride ion content - ion chromatography |
GB/T 14642-2009 | Industrial circulating cooling water and boiler water fluorine, chlorine, phosphoric acid, nitrite, nitric acid and sulfur |
GB/T 15454-2009 | Determination of sodium, ammonium, potassium, magnesium and calcium ions in industrial circulating cooling water - Ion chromatography |
GB/T 23710-2009 | Determination of sodium, ammonium, potassium, magnesium and calcium ions in industrial circulating cooling water - Ion chromatography |
GB/T 21533-2008 | Determination of starch syrups in honey by ion chromatography |
GB/T 20188-2006 | Determination of bromate in wheat flour by ion chromatography |
GB/T 13580.5-1992 | Determination of Fluorine, chlorine, nitrite, nitrate and sulfate in atmospheric precipitation by ion chromatography |
GB/T 32953-2016 | Determination of melamine content in fertilizer by ion chromatography |
GB/T 11733-1989 | Standard method for hygienic inspection of sulphates in the atmosphere of residential areas - ion chromatography |
1. Equipment use: canalization and anion analysis in samples
2. Configuration requirements
★2.1 Built-in pool column integrated constant temperature system [provide qualification documents] 1 set
2.2 One conductivity detector
2.3 1 set of high-pressure advection pump
2.4 One set of six-way sampling valves
2.5 One set of flow system
2.6 One anion separation column
2.7 One set of anion suppressor
2.8 One set of chromatographic workstations
2.9 1 set of accessories
3. Technical parameters
3.1 High pressure advection pump:
The microprocessor-controlled double-plunger reciprocating pump adopts advanced intelligent control algorithm, which can reduce the flow pulsation of the pump to the lowest level.
★3.1.1 Pressure test: ≥36MPa (JJG823-2014 "Ion Chromatograph Metrology Verification Regulations" shall prevail, and provide the type evaluation report and type approval certificate of measuring instruments issued in accordance with this regulation)
★3.1.2 Maximum pressure: 42MPa (provide measurement reports issued by provincial and above measurement departments)
★3.1.2 Flow range: 0.001ml/min ~ 15.000ml/min (provide measurement reports issued by provincial and above measurement departments)
3.1.3 Pressure sensor: pressure display accuracy ≤0.1MPa
3.1.4 Overpressure protection: When the working pressure exceeds or is lower than the set upper or lower limit, the pump will shut down and alarm.
3.2 Conductivity detector:
3.2.1 Pool volume: < 0.8ul.
3.2.2 Operating pressure: 10Mpa.
★3.2.3 Conductivity detection range: 0-60000uS, 1-8 adjustable, with manual and automatic file selection function. (Provide measurement reports issued by provincial and above measurement departments)
★3.2.4 Full range detection resolution: ≤0.0010ns/cm (provide measurement reports issued by provincial and above measurement departments)
3.3 Anion suppressor:
3.3.1 Continuous automatic regeneration electrochemical microfilm suppressor, online automatic regeneration, high inhibition capacity, low background conductance, low noise, baseline stability, maintenance-free.
3.3.2 Anti-pollution, good pressure resistance, long life, wide range of use (PH0-14).
3.3.3 Small size, fast stabilization time, stabilization time is not more than 12 minutes, and good reproducibility.
3.4 Flow path system:
3.4.1 The flow path system is made of PEEK material (imported parts), which has good versatility and can use strong acid and alkali eluent.
3.4.2 Compatible with 100% organic solvents, it is convenient for users to analyze, rinse and maintain complex samples.
3.5 Chromatographic Workstation:
3.5.1 24-bit high-precision and high-sensitivity digital-to-analog conversion.
3.5.2 Dedicated ion chromatographic workstation, full Chinese display, digital signal transmission with computer through high-performance USB, to complete cationic data acquisition and processing.
3.5.3 Instrument counter-control operation can be realized, instrument working parameters can be set online through the computer, and man-machine dialogue can be conducted.
3.5.4 Automatically receive analysis and control preservation instrument chromatographic conditions.
3.5.5 Automatic negative peak identification and baseline deduction function. Automatic parameter integration, automatic report generation.
3.5.6 Automatically detect the running status of the instrument, give an alarm to the running fault and provide protective measures for the instrument.
3.6 Test technical indicators: (JJG823-2014 "Ion Chromatograph Metrology Verification Regulations" shall prevail, and provide the type evaluation report and type approval certificate of measuring instruments issued in accordance with this regulation)
Anions: Seven anions such as F-, Br-, Cl-, SO42-, NO3-, NO2- and HPO42- can be analyzed in one sample
★3.6.1 Minimum detection limit: (provide measurement reports issued by provincial and above measurement departments)
★ 3.6.1.1Cl -≤0.0001μg/mL
★3.6.1.2 Li+≤0.0001μg/mL
3.6.2 Linear correlation coefficient ≥0.999
★3.6.3 Linear range: ≥103(in Cl-)
★3.6.4 Baseline noise: 0.0003μS/cm (provide measurement reports issued by provincial and above metrology departments)
★3.6.5 Baseline drift: 0.003μS/30min (Provide measurement reports issued by provincial and above metrology departments)
★3.6.6 Qualitative repeatability: ≤0.02% (provide measurement reports issued by provincial and above measurement departments)
★3.6.7 Quantitative repeatability: ≤0.2% (provide measurement reports issued by provincial and above measurement departments)
★3.6.8 Column temperature box temperature stability: ≤0.1ºC/h
4. Performance indicators:
(1) The instrument operating system is completed by one click of the mouse, with automatic selection of range, automatic zero setting, current setting and other functions.
(2) In the large-screen program of the instrument, there is a small workstation to display spectrogram processing data and save spectrogram data.
5, the instrument working environment:
Voltage: AC220V±10% 50HZ
Temperature: 10~30ºC
Humidity: 25~85%