Customization: | Available |
---|---|
After-sales Service: | Online |
Warranty: | 1 Year |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | A (A~D) |
B (A~D) |
C (A~D) |
D (A~D) |
E (A~D) |
F (A~D) |
Inner size: WHD(cm) | 40*35*30 | 50*30*40 | 50*40*40 | 50*50*40 | 60*40*50 | 60*50*50 |
External size: WHD(cm) | 150*180*150 | 160*175*160 | 160*185*160 | 160*185*170 | 170*185*170 | 170*195*170 |
Temperature range(Test Chamber) | high temperature:+60ºC~+200ºC;low temperature -10ºC~-65ºC(A:-45ºC;B:-55ºC;C:-65ºC) | |||||
Heating Time | RT~200ºC About 30min | |||||
Cooling Time | RT~-70ºC About 85min | |||||
Temperature Conversion Time | Less than 10S | |||||
Temperature Recovery Time | Less than 5min | |||||
Temperature Deviation | ±2.0ºC | |||||
Temperature Fluctuation | ±0.5ºC | |||||
Material | External material: SUS#304 Stainless steel plate Internal material:SUS#304Stainless steel plate |
|||||
Output Mode | Water-cooled or air-cooled,Taikang compressor in France | |||||
Controller | TEMI South Korea | |||||
Cooling System | Water-cooled or air-cooled,Taikang compressor in France | |||||
Protection devices | Fuse switch, compressor overload switch, refrigerant high and low pressure protection switch,super humidity over-temperature protection switch, fuse, failure warning system |
|||||
patrs | Watching window;50mm testing hole; partition plat | |||||
Power | AC380V 50/60Hz Three-phase four-wire ac power | |||||
weight (kg) | 750 | 790 | 830 | 880 | 950 | 1050 |
1.Profile. | |
1.1 Item | Thermal shock test chamber (three zone) |
1.2Model | GA-2010 |
1.3Sample restrictions |
The equipment is prohibited to do the test and storing as below:
|
1.4 Test condition | Envrionmental temperature: +25ºC; humidity: ≤85%, with no samples inside the chamber |
1.5 Test method | GB/T 5170.2-1996 temperature test chamber and so on |
1.6 Meet the test standard | Meet GB2423, IEC68-2-14, JIS C 0025, MIL-STD-883E, IPC 2.6.7, BELLCORE and other standards |
2.Technical parameters. | |
Inner size (WxHxD)mm | 400×350×300mm |
Inner volume | 42L |
External size (WxHxD)mm | 1550x1650x 1470mm |
Preheating temperature | +60ºC~+200ºC (heat up +25ºC~+200ºC/ 20min) |
Precooling temperature | -10ºC ~-45ºC (cooling +25ºC~-45 ºC/65min) |
High temp. shock range | +60ºC~+150ºC |
Low temp. shock range | -10ºC~-40ºC |
Temperature fluctuation | ±0.5ºC |
Temperature deviation | ±2.0ºC |
Shock recovery time | ≤5min (control point) |
3. Structure | |
3-1. Inner & External chamber material | Inner / External chamber: stainless steel plate (SUS # 304) |
3-2. Main structure design | Divided into low temperature storing area, product testing area, high temperature heat storing area. |
3-3. Cooling storage / heating storage material | High efficiency aluminum enable heat storage capacity and super-cold capacity to reach super fast exchanging. |
3-4.Environmental conditions | Meet MIL , IEC , JIS ,IPC etc. and the specifications of the chamber |
3-6. Testing hole | For connecting external testing wire and signal (10.0cm) of 1 piece |
3-7. Table running wheel | Moving position adjustbale and forced fixed knot position (500kg/wheel) |
3-8. Thermal insulating layer | Burning fire resistant thermal insulation layer PU + thermal insulation wool (thermal insulation thickness of 12.0 cm) |
3-9. Frame inside chamber | Height adjustable grid shelves and stainless steel mesh grid plate (2pcs, separation distance of 5.0cm ) |
4.Supply air circulation system | |
4-1.Electric heating circulatory system | utilize circulatory motor of special moisture-proof, with stainless steel extension axis. |
4-2. Circulating fan | High/low temperature resistance aluminum alloy multi-wing centrifugal wind wheel. |
4-3. High evenness air flue | Positive pressure outlet design to achieve high uniformity requirements. |
4-4. Temp. electric heating control | Balanced temp. P.I.D + P.W.M + S.S.R system. |
4-5. Microcomputer control | Microcomputer control, pre-cooling zone, preheating zone and temperature conversion in the test zone, output power which is calculated by computer to achieve high accuracy and high efficiency electricity. |
5.Refrigeration system | |
5-1. Refrigeration device | ![]() |
5-2. Hot and cold switching device | Taiwan (Kaori) ultra-efficient 316# stainless steel plate cold & heat refrigerant exchanging design. |
5-3. Heating load regulation | Adjust the flow of refrigerant by microcomputer automatically which takes heat load effectively for the samples waiting to be tested; compared to the traditional design, it improves control stability and reproducibility, also achieves power saving to get super efficiency. |
5-4. Condenser | ![]() |
5-5.Effeciency super freezing control refrigerant | Refrigerant pipes are welded with pressurized nitrogen and passed leak test. |
5-6. Evaporator | Slope evaporator with high efficiency component (AC & R double spoiler aluminum fins). |
5-7. Standard modular | Compatibility and interoperability of components of high quality and stability. |
5-8.Expansion of performance | The control system can reserve isothermal control Liquid nitrogen valve LN2V and refrigerant valve FV control interface. |
6.Control system | |
6-1 Controller | |
A.Temperature sensor | T-type rapid induction sensor. |
B.Temperature converter | Automatic correction of linear compensation temperature converter by microcomputer |
C.Display panel | ![]() |
D.Control mode | Touch control screen (100,000 times of line drawing test) |
E.Storing device | USB2.0 Interface & R-232C bidirectional control and computer hard drives data store. The controller with 60 seconds for sample calculation which can record historical data and curve within 60 days. ![]() Test curve download Test data download |
F.Humanized operation interface | A.I. + Fuzzy control interface functions. |
a. Auto-control | Refrigeration compressors with refrigerant automatic servo control, temperature electric heating, PID, PWM, SSR and so on. |
b. Safety device | Detecting faults of all parts and alarm shutdown function |
G.Expansion interface and control apparatus (the following function is optional and should be paid, details refer to the contract) | |
a. PCOperation system | Record storage, curve, historical data through the RS232 interface and can be analyzed / Print / E-mail / hard disk storage. |
b.Liquid nitrogen interface | Liquid nitrogen ( LN2 ) control interface device . |
c. Programmable control interface |
Relay 220V 3A * 2 group, programmable logic external drive assembly output. (ON / OFF) (Signal, institutions, power-related auxiliary control etc.) |
d. Internet remote monitoring interface | ![]() ![]() Working condition can be remotely monitored and operated via the internet. |
6-2. Main function of the controller | |
A.Temperature analytical ability | 0.1 ºC |
B.Temperature control precision | ±0.2 ºC |
C. Time range set | 0 H 1 M ~ 9999 H 59 M |
D. Memory capacity | 96 PROGRAM×3200 CYCLE |
a. FUNCTION 1 |
Positive and negative temperature shock Low temp. shock High temp. shock |
b. FUNCTION 2 | Run high-temperature storage independently |
c. FUNCTION 3 | Run low-temperature storage independently |
d.Power-saving operation mode (1) | Microcomputer controls refrigerant flow rate with intelligent servo to save power. |
e.Power-saving operation mode (2) | When high-temperature set period is longer than two hours, compressor shutdown for waiting; When low-temperature set period is longer than two hours, high temperature tank shutdown for waiting; |
E. Display language | Chinese(S) / English (colorful TFT operation / fault cause / troubleshooting) |
F. Set-up time reservation | Set-up time seting function |
G. Calculation control | Execute temperature shock program changing control and connection control program automatically |
H. Page display | Full-color real-time curve display (set curve and actual value curve).![]() |
I.Fault record device software | Machine maintenance real-time control storage/record/ analysis / e-mail |
J.Controller deviation setting | Intelligent digital temperature deviation "zero." |
K. Choice after recovery from outage | Choose "continue", "again", "stop" after outage or recovery. |
L.Program complete choice | After the process completed, select the settings of "cold storage", "high-temperature storage", "linked to another group" . |
M. Optional skip function | It can jump to the next segment during program running |
N.Control calculation software | Adjust the flow of refrigerant by microcomputer automatically which takes heat load effectively for the samples waiting to be tested; compared to the traditional design, it improves control stability and reproducibility, also achieves power saving to get super efficiency. |
O.High and low temperature protection upper limit | high and low temperature protection limit can be set during test procedures. |
P. Auto-impact/defrost | Suspend defrost and impact manually during automatic operation |
Q. Protection device | The controller monitors security systems and preventive fault detecting control interface automatically |
R.Power-cut memory device | Ensure the program memory data stored during power outage |
S. Fool-proof design within the capacity range | Display control capabilities of machine, with the display of fool-proof design that exceeds the ability range. |
T.Security permissions settings | Machine operation password permissions. |
U. With screen protector | screen protector |
7.Safety protection device | |
7-1.Leakage / surge prevention protection | LG leakage circuit breaker protection FUSE.RC electronic surge protected. |
7-2. Over load protection device | AC Power source Three-phase power supply due to lack or inverse phase and overcurrent protection (overload) |
7-3.Auto-detection protection device equipped inside the controller | A. Microcomputer data transmission detection DATA CHEAK SUM B. Temp. sensor-(Sensor) Open or short circuit (+ - OVER) C. Controller internal temperature limit for the first layer of high temperature, low temperature and over-temperature protection settings. |
7-4. Fault detecting control interface External fault auto-detection and protection device A. Panel high temperature and over-temperature protection setting, the second layer with high temperature over-temperature electronic protection device B. Hot groove/cold groove/anti-dry protection, the third layer with high temperature over-temperature protection. C. Compressor protection - refrigerant pressure protection and overload protection device. D. Compressor protection - overheating protection and device. E. Pressure protection device - pneumatic drive mechanism pneumatic pressure source protection and cooling water pressure protection device. |
|
7-5. Fault protection Turn off the power due to malfunction and output alarm signal |
|
8.Professional production technology | |
8-1. All components modularization or standardized manufacturing. | |
8-2. Nitrogen refrigeration system welding, precision instruments nitrogen pressurization test. | |
8-3. Japanese vacuum pump and American precision digital instrument to do vacuum test. | |
8-4. Microcomputer controller: temperature inspection instrument | |
8-5. Temperature electric heating controls electric power test and insulation resistance test (above 50 M Ohm / 500 DCV) | |
8-6. Each machine before leave factory need a burn-in test up to 7 days. | |
9.Precautions (The buyer will be responsible for configuring the chamber next to the machine) | |
9-1. MAX 380V/50Hz, 3Φ, 5 Wire, 85A. (Voltage range less than ±10%) | |
9-2. Air pressure source - 1/2 HP compressor available around 10m distance, with pressure not less than 5Kg / CM2. |
10.Core parts. | |||||
No. | Parts | Origin/brand | No. | Parts | Origin/brand |
1 | Controller | Taiwan/ Delta | 12 | Temp. sensor | Japan/DIN |
2 | Compressor | Germany/GEA | 13 | evaporator | Japan/Shuangling |
3 | condenser | Japan /Shuangling | 14 | S.S.R | TW/CKC |
4 | Condenser draught fan | Germany/Mahr | 15 | Internal & external chamber material | Japan/Denshi |
5 | Expansion valve | Denmark | 16 | Wind cylinder | TW/Sunrise |
6 | Solenoid valve | Denmark | 17 | Wind wheel | TW/Guangshuo |
8 | Plate-type heating converter | TW/Kaori | 18 | Heating tube | TW/TAIE |
9 | Cycle motor | TW/MOTOR | 19 | Thermo relay | Korea /LG |
10 | Oil separator | USA/AICO | 20 | Solid-state relay | Korea /LG |
11 | Overtemperature protection device | Japan | 21 | Main switch | Japan/ MITSUBISHI |