Full-automatic Touch Screen Oxygen Index Test Equipment Tester Oxygen Indexer GA-9007

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 year
Still deciding? Get samples of US$ 1000/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (7)
  • Full-automatic Touch Screen Oxygen Index Test Equipment Tester Oxygen Indexer GA-9007
  • Full-automatic Touch Screen Oxygen Index Test Equipment Tester Oxygen Indexer GA-9007
  • Full-automatic Touch Screen Oxygen Index Test Equipment Tester Oxygen Indexer GA-9007
  • Full-automatic Touch Screen Oxygen Index Test Equipment Tester Oxygen Indexer GA-9007
  • Full-automatic Touch Screen Oxygen Index Test Equipment Tester Oxygen Indexer GA-9007
  • Full-automatic Touch Screen Oxygen Index Test Equipment Tester Oxygen Indexer GA-9007
Find Similar Products

Basic Info.

Model NO.
GA-9007
Type
Oxygen Index Test Equipment
Weight
29KG
Power Source
AC220V
Input pressure
0.25-0.3mpa
Transport Package
Plywood Case
Specification
80cm*40*102cm
Trademark
GONOAVA
Origin
Hunan
HS Code
9024800000
Production Capacity
200

Product Description

Full-automatic Touch Screen Oxygen Index Test Equipment Tester Oxygen Indexer GA-9007
Product advantages:

1. Full-color touch screen control, as long as the oxygen concentration value is set on the touch screen, the program will automatically adjust to the oxygen concentration balance and issue the sound of beep, eliminating the trouble of manually adjusting the oxygen concentration;One key calibration oxygen concentration, data storage
2. The stepping proportional valve is adopted to greatly improve the control accuracy of flow rate. The closed-loop control is adopted to automatically adjust the oxygen concentration drift program back to the target value during the test.
3. The equipment has its own fume hood, which can automatically exhaust smoke;

Full-automatic Touch Screen Oxygen Index Test Equipment Tester Oxygen Indexer GA-9007
Technical parameters

1.Imported oxygen sensor, digital display oxygen concentration without calculation, higher accuracy and more accurate, range 0-100%
2.Display accuracy: ±0.01
3.Touch screen setting program automatically adjusts oxygen concentration
4.One key calibration accuracy
5.One bond ratio
6.Stable oxygen concentration automatically prompts alarm sound
7.With timing function
8.Experimental data can be stored
9.Historical data can be queried
10.Clear historical data
11.Optional whether to burn 50mm
12.Air source fault prompt
13.Oxygen sensor fault indication
14.Oxygen nitrogen wrong connection prompt
15.Oxygen sensor aging tips
16.Standard oxygen concentration input
17.Diameter of combustion cylinder can be set (two common specifications are optional)
18.Flow regulation range: 0-20l /min (0-1200l /h)
19.Quartz glass tube: two specifications either (diameter 75 mm or inner diameter  85 mm)
20.Gas velocity in combustion cylinder: 40mm ± 2mm/s
21.Overall dimensions: 80cm*40*102cm
22.Automatic smoke exhaust pipe outer diameter: 7.6cm
23.Pressure gauge accuracy 2.5, resolution: 0.01MPa
24.Test environment: the environment temperature: room temperature ~ 40 ºC;, relative humidity: no more than 70%;
25.Input pressure: 0.25-0.3mpa
26.Working pressure: nitrogen 0.15-0.20mpa oxygen 0.15-0.20mpa
27.Propane (butane) ignition system, the ignition nozzle is made of a metal, the end has Φ 2±1 mm inner diameter nozzle, can be bent freely.Can be inserted into the combustion cylinder to light the sample, the flame length: 16 ± 4mm, the size of 5mm-60mm can be adjusted freely,
28.Gas: nitrogen and oxygen for industrial use, purity of > 99%;(the purity of industrial oxygen in user-provided/normal gas stations is generally between 99.2% and 99.3%).
29.Power requirements: AC220 (±10%) V, 50HZ
30.Maximum power: 150W
31.Self-supporting material sample holder: it can be fixed on the axis of combustion cylinder and can hold the sample vertically
32.Non-self-supporting material sample clip: can fix two vertical edges of the sample on the frame at the same time (optional/applicable to soft non-self-supporting material such as textile)
33. It can be upgraded to the Internet of things function: it can control and read data through the router, save data to the computer and print reports

Full-automatic Touch Screen Oxygen Index Test Equipment Tester Oxygen Indexer GA-9007
Full-automatic Touch Screen Oxygen Index Test Equipment Tester Oxygen Indexer GA-9007Full-automatic Touch Screen Oxygen Index Test Equipment Tester Oxygen Indexer GA-9007Full-automatic Touch Screen Oxygen Index Test Equipment Tester Oxygen Indexer GA-9007

Full-automatic Touch Screen Oxygen Index Test Equipment Tester Oxygen Indexer GA-9007Full-automatic Touch Screen Oxygen Index Test Equipment Tester Oxygen Indexer GA-9007

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier