Best Quality Automatic Wet Automatic Laser Particle Size Analyzer ISO13320

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 Year
Still deciding? Get samples of US$ 5000/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (7)
  • Best Quality Automatic Wet Automatic Laser Particle Size Analyzer ISO13320
  • Best Quality Automatic Wet Automatic Laser Particle Size Analyzer ISO13320
  • Best Quality Automatic Wet Automatic Laser Particle Size Analyzer ISO13320
  • Best Quality Automatic Wet Automatic Laser Particle Size Analyzer ISO13320
  • Best Quality Automatic Wet Automatic Laser Particle Size Analyzer ISO13320
  • Best Quality Automatic Wet Automatic Laser Particle Size Analyzer ISO13320
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
Overview

Basic Info.

Model NO.
GA-2606-A
Mass Scope of Workpiece
<900kg
Type
Particle Size Analyzer
Maxcapacity
<1000KN
Accuracy Grade
0.1 Mu M - 360 Microns
Load Way
Electronic Load
Display
Digital
Control
Manual Control
Weight
30kg
Power Source
P =100W
Transport Package
Plywood Cases
Specification
850mm*410mm*450mm
Trademark
GONOAVA
Origin
Changsha
HS Code
9024800000
Production Capacity
200

Product Description

 
Product Description

Best quality Automatic Wet Automatic Laser Particle Size Analyzer ISO 13320
1. Introduction

GA-2606-A is the latest product researched and developed by our company. Based on GA-2606-A , a large number of upgrades have been carried out, and it has won unanimous praise from customers since its launch. GA-2606-A is a wet automatic laser particle size analyzer, which adopts the most advanced Mie scattering principle and the concentrating Fourier transform light path. High-density probe and full range seamless test method ensure the accuracy and repeatability of test results.

Best quality Automatic Wet Automatic Laser Particle Size Analyzer ISO 13320
2. Performance characteristics

Advanced optical path design: GA-2606-A uses concentrating Fourier transform testing technology to ensure the shortest focal length to obtain the maximum range, effectively improve the resolution of the instrument; The unique high-density detection unit enables THE GA-2606-A  to have super small particle testing capability. The high-density detection unit enables the GA-2606-A  to have super seamless full-range testing capability.
Enable new software: three generations of software officially commercial, new software optimization algorithm, more accurate test results, higher stability, real-time storage of test data will never be lost; Third generation software support fuzzy search function, all tested samples can be easily found no matter how long; Human-computer interaction is more reasonable.
Four generation detector: 5200 particle size instrument at the same time enabled the fourth generation detector, all using German imported materials processing, strong oxidation resistance, photoelectric conversion efficiency more than ten years almost zero attenuation.
GA-2606-A fully sealed fiber semiconductor laser GA-2606-A uses the high stability, long life Of Japan Opnext fully sealed fiber semiconductor laser, excellent stability so that GA-2606-A has a strong test repeatability, on the basis of 5100-H do laser power adjustable, the maximum laser power is also achieved 20MW.
 Laser intelligent management system: GA-2606-A takes the lead in increasing the laser intelligent management system, intelligent management system real-time monitoring of the working state of the instrument, once received the command of the work of the intelligent management system will instantly light up the laser, high-performance laser will reach a stable working state in 3 seconds. After the sample test, the intelligent management system will automatically shut down the laser, and the laser will basically not attenuate. Theoretically, the particle size analyzer can live without replacing the laser (optional).
 Automatic test: truly automatic test, what you do is just put in the sample, no interference data without manual selection of data.
 Ultrasonic anti-dry burning function: after painstaking research and development, GA-2606-A can realize ultrasonic anti-dry burning function, to avoid damage to ultrasonic in the case of no water.
New SOP self-editing function: In order to meet the test needs of different samples, GA-2606-A 6 realizes the SOP self-editing function, edit different test procedures according to different samples, edit and save once and then directly use next time.
Dustproof and shockproof design: the whole instrument is sealed to greatly improve the service life of the internal components. The unique shockproof structure can effectively avoid the interference of external vibration to the instrument, so that the test results are more stable and reliable.
Strong anti-corrosion design (optional) : according to the actual needs of customers can be equipped with acid resistance, alkali resistance, oil resistance (including all solvent oil), resistance to organic solvents (such as acetone, phenol, n-hexane and other organic solvents).
 Optical path automatic calibration: self-developed new automatic alignment system including stepper motor, precision guide rail, precision controller and software system, minimum step distance of 1 micron, to ensure that the laser beam focus from the center point through the detector, improve the accuracy of test results and repeatability. Automatic centering system is the standard configuration of all types of Laser particle size meter.
Unique microcirculation system: the whole dispersion circulation system has been optimized design, the dispersion medium is greater than 80 ml can cycle test, really achieve the microcirculation test; The optimized design ensures no waste residue after drainage and the accuracy of the next test result. (Optional for microtest)
 Free exhaust bubble design: the new design makes the whole test will not have bubble into the test sample window, avoid bubble interference.
Dew point measurement function: the system is equipped with dew point measurement function, the software can provide sample window fog reminder according to the change of the environment; The instrument also has the function of internal temperature, humidity and test medium temperature display.
organic solvents (such as acetone, phenol, n-hexane and other organic solvents).
★ Dispersant automatic filling system: the new 5200 increased the dispersant automatic filling system, greatly improving the stability of the instrument dispersion; It not only avoids the tedious artificial addition but also greatly prolongs the cleaning cycle of the sample window (if there is no lack of dispersant calcium carbonate industry can basically not clean the sample window).
 Channel steel guide: the new 5200 light path guide is uniformly upgraded from aluminum alloy to thickened channel steel, the light path system is more stable and reliable, and greatly reduces the influence of temperature and humidity on the light path.
★ Sample no residue design: the instrument pipeline and drainage structure are optimized design, the instrument pipeline, circulation pump no liquid residue, to avoid the impact on the next test data.
★ Sample window quick change device: newly designed sample window quick change device, make sample window more convenient and fast change.

Product Parameters
Best quality Automatic Wet Automatic Laser Particle Size Analyzer ISO 13320
3. Technical Specifications  
specifications GA-2606-A (With high)
Execution standard ISO 13320:2009
Test range 0.1μm -800μm
Number of detector channels 70
Accuracy error 1% (National standard sample D50 value)
Repeatability error < 0.5% (National standard sample D50 value)
Free bubble With no exhaust bubble design, no bubble interference data more accurate
Misoperation protection The instrument has self-protection function for misoperation and does not respond to misoperation
Laser parameter Imported fiber output high power laser λ= 635nm, P> 10mW
The light path calibration Automatic optical path calibration
Dispersion method ultrasonic Frequency: F =40KHz, power: P =80W, time: adjustable; With ultrasonic anti-dry burning
Circulating and stirring Integrated design of circulation mixing, speed: 100-3950 RPM adjustable speed
Circular flow Rated flow: 0-10L/min Adjustable rated power: 25W
The sample pool Self-designed boiling sample tank, better dispersion effect, capacity: 190-600ml can be normal test
Microinjection (optional) The instrument can be equipped with micro automatic test device,10 ml can be cyclic test (optional)
Dustproof and shockproof design The whole machine adopts dustproof and shockproof design
Anti-corrosion design (optional) Can be equipped with acid resistance, alkali resistance, oil resistance (including all solvent oil), resistance to organic solvents (such as acetone, phenol, n-hexane and other organic solvents).
Software functions Analysis patterns Including free distribution, R-R distribution and log-normal distribution, classification by order statistical mode, etc., to meet the different requirements of different industries for sample size statistical methods
Statistical methods Volume distribution and quantity distribution, in order to meet the different statistical methods of granularity distribution in different industries
Statistical comparison It can make statistical comparison and analysis for multiple test results, and can obviously compare the difference of test results of different batches of samples, samples before and after processing and different time, which has strong practical significance for the quality control of industrial raw materials
To DIY User-defined data to display, according to the percentage of particle size, according to the percentage of particle size or according to
According to the template The percentage of particle size interval is calculated to meet the characterization of particle size test in different industries. Diameter distance, consistency, interval accumulation, etc
The test report The test report can be exported to Word, Excel, Bmp, and Text files, enabling you to view test reports and reference test results in scientific research articles on any occasion
Multilingual support Chinese and English language interface support, can also be embedded in other languages according to user requirements.
Intelligent operation mode Truly automatic unmanned intervention operation, no human interference, you only need to add the sample to be tested as prompted, the test results of better repeatability.
Operating mode One-click automatic software operation mode
The test speed < 1min/ time (excluding sample dispersion time)
volume 850mm*410mm*450mm
The weight of the 30Kg
Detailed Photos
Best Quality Automatic Wet Automatic Laser Particle Size Analyzer ISO13320
Company Profile

 

Best Quality Automatic Wet Automatic Laser Particle Size Analyzer ISO13320

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier