DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester

Hunan Gonoava Instrument Co Ltd
  • Audited Supplier
  • 3 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Online Temperature Calibration: Unique technology improves accuracy by over 3 times with simple and fast calibration.
  • Automatic Thickness Measurement: Computer-controlled automatic measurement reduces human error with 0.001mm resolution.
  • Customizable Specimen Thickness: Sample thickness up to 100mm can be customized according to contract.
  • One Year Free Warranty: Includes one year free warranty with long-term technical services and lifetime software upgrades.
  • Free On-site Installation: Free on-site installation and debugging available throughout the country.
  • Fast Test Cycle: Whole process test time is 60 minutes, greatly shortened by unique calibration technology.

Product Images of DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester

DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester pictures & photos
DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester pictures & photos
DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester pictures & photos
DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester pictures & photos
DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester pictures & photos
DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester pictures & photos
DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
  • DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
    DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
  • DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
    DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
  • DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
    DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
  • DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
    DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
  • DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
    DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
  • DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
    DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester

Find Similar Products

Product Description

DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
1.Product introduction

The thermal conductivity tester mainly tests plastic, rubber, glass, fiber, benzene board, extrusion board, foams concrete, hollow glass, wood, all kinds of thermal insulation materials and other uniform plate materials, while measuring the thermal conductivity of granular material, bulk material, soft material and other substances. Applicable standard: GB/T10294-2008 "Determination of steady-state thermal resistance and related characteristics of thermal insulation materials"; GB/T3399-1982 "plastic thermal conductivity test method - heat protection plate method"; GB/T10801.1-2002 "Polystyrene foam for thermal insulation" specified in the measurement of thermal conductivity of polyurethane rigid foam materials; GB/T10801.2-2002 "Extruded polystyrene foam for insulation (XPS)" specified in the extruded polystyrene foam thermal conductivity measurement; GB/T3139-2005 "fiber reinforced plastics thermal conductivity test method"; GB/T 17794-2008 "flexible foam rubber insulation products";
Product Parameters
DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
2. Product Parameter
 
 
thermal conductivity
measurement range
0.001 ~ 3.000 W/m.K.
 measurement accuracy
 
 
 ≥ ± 2% ≥ ± 2%
repeatability error ≤ ± 1%
 
hot surface temperature
 measurement range
 
room temperature ~ 150ºC (standard configuration), resolution: 0.01ºC. Room temperature ~ 500ºC can be customized according to the contract. Cold surface temperature measurement range: 0 ~ 60ºC, resolution: 0.0 1ºC.
 
thickness measurement range
 
0 ~ 50mm (standard configuration), resolution: 0.001mm, automatic digital thickness measurement. 100mm can be customized according to the contract.
 
pressure measurement range
 
0 ~ 500N, resolution: 0.1N. Pressure can be accurately set and automatic control and display.
 
 Specimen size
 
300 x 300 x (5 ~ 50) mm (standard configuration). Sample thickness of 100mm can be customized according to the contract.
 
the whole process test time
 
60 minutes.
 
power supply power
 
220V 50HZ. 500W.
 
full computer automatic detection and data processing system, compatible with the general computer.

DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
3.Features

Online temperature calibration: unique technology, calibration instrument is simple and fast, the accuracy is improved by more than 3 times.

The whole process test time is greatly shortened.
Large measuring range: range 0.001 ~ 3.00w/(m.k).

Automatic thickness measurement: computer automatic thickness measurement, reduce human error.
Automatic pressurization system: computer accurate automatic pressurization, can test the thermal conductivity under different pressures, more scientific than manual pressurization, more data, better repeatability.

★ Many types of measurement: in addition to measuring hard plates, the company's various accessories can be selected to measure a variety of special materials. For example: granular material, bulk material.

DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
4.complete set


1. One host computer;

2. A set of analysis software (Chinese and English versions);

3, HX-1005 precision low temperature constant temperature tank one (temperature control accuracy 0.01ºC);

4, a desktop Lenovo computer (users can choose);

5. A standard sample;

4. Dimensions and weight

1. Host: standard landing model: (length × width × height) 550×450×1500mm, net weight: 100Kg.

2, precision low temperature constant temperature tank: (length × width × height) 300×350×530mm, net weight: 35Kg.

DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
5.Technical services


1, one year free warranty, long-term technical services, software lifetime free upgrade.

2. Free on-site installation and debugging throughout the country. All over the country has the company's mobile technical personnel, can provide technical services.
Detailed Photos

DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester
DRH-V automatic double plate thermal conductivity measuring instrument Thermal conductivity tester

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASI249867". Items marked "verified" are certified.

Watch Video
Watch Video
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd

About Our Factory & Business Background

verified Business Type
Trading Company
Address
Room 2318, Building 29 Yingyuewan, Runhe Yicheng Yueliangdao Street, Wangcheng, Changsha, Hunan, China
verified Plant Area
120 square meters
verified Number of Employees
8
verified Terms of Payment
T/T, LC, D/P, PayPal, Small-amount payment, Western Union
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port
verified Minimum Order Quantity
1 Piece
verified Supply Chain Partners
9

Our Production Capability & Technical Expertise

verified Main Products
Differential Scanning Calorimeter; Gas Chromatograph; Vacuum Type Dilatometer; Tensile Strength Tester
verified Customization Options
Customization from Samples
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2023-04-06
verified Export Year
1 Year
verified Main Markets
North America, Southeast Asia/ Mideast, East Asia(Japan/ South Korea)
verified Repeat Buyers Choice
< 10%
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
No

Our Certifications, Standards & Industry Recognition

verified Cooperated with Fortune 500
No

FAQ

What is the warranty period for this instrument?
We provide a one-year free warranty, along with long-term technical services and lifetime free software upgrades.
Is on-site installation included?
Yes, free on-site installation and debugging are provided throughout the country by mobile technical personnel.
What materials can this tester measure?
It measures plastic, rubber, glass, fiber, foams, concrete, wood, and granular or bulk materials.
What is the standard specimen size?
The standard specimen size is 300 x 300 x (5 ~ 50) mm, with thickness up to 100mm customizable.
What is the lead time for orders?
The average lead time is within 15 workdays for both peak and off-peak seasons.
What payment methods are accepted?
Accepted payment terms include T/T, LC, D/P, PayPal, Small-amount payment, and Western Union.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Product Groups

Product Catalogs