Ga-8621anionic Scheme Ion Chromatograph Tester Pdhid Photoelectric Detection Equipment

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 Year
Still deciding? Get samples of US$ 9850/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (7)
  • Ga-8621anionic Scheme Ion Chromatograph Tester Pdhid Photoelectric Detection Equipment
  • Ga-8621anionic Scheme Ion Chromatograph Tester Pdhid Photoelectric Detection Equipment
  • Ga-8621anionic Scheme Ion Chromatograph Tester Pdhid Photoelectric Detection Equipment
  • Ga-8621anionic Scheme Ion Chromatograph Tester Pdhid Photoelectric Detection Equipment
  • Ga-8621anionic Scheme Ion Chromatograph Tester Pdhid Photoelectric Detection Equipment
  • Ga-8621anionic Scheme Ion Chromatograph Tester Pdhid Photoelectric Detection Equipment
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
GA-8621
Display
Digital
Weight
0-100Kg
Power Source
AC220V
Transport Package
Plywood Case
Trademark
GONOAVA
Origin
China
HS Code
9024800000
Production Capacity
200

Product Description

Product Description
Factory direct sales Dual system ion chromatograph anion cationic tester Analyzer
1.Description
GA-8621 Ion Chromatograph is a professional instrument developed by our company to meet the needs of users for the detection of high-low concentration components in various fields. It can detect various cations and ions in samples under different leaching conditions. Because the range can be automatically shifted, it can take into account high and low concentration samples, reduce the dilution ratio of high concentration samples, reduce the complexity of pre-processing, and reduce the error of detection results, and is the preferred equipment for inorganic ion analysis in various monitoring fields.

Main performance
★ Integrated design, large touch screen display, instrument constant temperature measures optimization, high instrument accuracy, good stability;
★ Integrated ion chromatography workstation; The main machine, automatic sampler and eluent generator three parts of the operation interface, clear interface, easy operation, good application experience;
★ Highly sensitive circuit system, instrument detection sensitivity and stability is high, can meet the diversified testing needs of users;
★ High precision constant temperature system, shorten the baseline stability time, improve instrument stability;
★ High pressure PEEK pump for ion detection (maximum pressure 35MPa, acid and alkaline leaching solution corrosion resistance);
★ Advanced inhibition technology, continuous automatic regeneration electrochemical suppressor, high inhibition capacity, automatic regeneration, fast balance, long life;
★ Compatible with all kinds of automatic sampler;
★ Optional Yin and Yang shower generator, electrolytic way to produce different concentrations of shower, no longer need manual configuration;
★ Compatible with all kinds of domestic C&D columns, imported C&D columns, etc.
★ Standard online degassing to achieve automatic degassing, no longer need manual degassing, real-time online degassing;
★ High pressure electric six-way valve, accurate switching, easy operation, long service life;
★ Support solvent switching function, support timing maintenance function, support automatic flushing automatic shutdown function;
★ Abe detector and UV detector can be selected according to demand.

Detection range
1) Anions: fluorine, chlorine, bromine, iodine, nitrite, nitrate, bromic acid, chlorate, chlorite, perchlorate, sulfate, sulfite, phosphate, monochloroacetic acid, dichloroacetic acid, trichloroacetic acid, monobromoacetic acid, dibromoacetic acid, small molecular organic acid (formic acid, acetic acid, propionic acid, acrylic acid, oxalic acid) anions and glyphosate, etc.
2) Cations: lithium, sodium, ammonium, potassium, magnesium, calcium and other cations and methylamine, dimethylamine, trimethylamine, isopropylamine detection.
Implementation standards:
GB/T5750.1-2023 Standard test method for drinking water
HJ799-2016 Determination of Water-soluble anions (F-, Cl-, NO2-, Br-, NO3-, PO43-, SO32-, SO42-) in ambient air particles by ion chromatography
HJ 549-2016 Determination of hydrogen chloride in ambient air and exhaust gas - Ion chromatography
HJ644-2016 Determination of sulfuric acid fog in the exhaust gas of stationary pollution sources by ion chromatography
HJ84-2016 Water quality determination of inorganic anions (F-, Cl-, NO2-, Br-, NO3-, PO43-, SO32-, SO42-) by ion chromatography
HJ1050-2019 Water quality - Determination of chlorate, chlorite, bromate, dichloroacetic acid, trichloroacetic acid - Ion chromatography
HJ688-2019 Determination of hydrogen fluoride in waste gas from stationary sources by ion chromatography
HJ1040-2019 Determination of hydrogen bromide in waste gas from stationary sources - Ion chromatography
Determination of soluble cations (Li+, Na+, NH4+, K+, Mg2+, Ca2+) in water of HJ812-2016 by ion chromatography
HJ800-2016 Determination of Water-soluble cations (Lithium, sodium, ammonium, potassium, magnesium, calcium) in ambient air particles by ion chromatography
HJ 1005-2018 Determination of cations (Na+, NH4+, K+, Mg2+, Ca2+) in ambient air precipitation by ion chromatography
HJ1041-2019 Determination of trimethylamine in the exhaust gas from stationary sources by ion chromatography
HJ1076-2019 Determination of ammonia, methylamine, dimethylamine, trimethylamine in ambient air - Ion chromatography
HJ778-2015 Water quality determination of iodide - Ion chromatography
HJ 1004-2018 Determination of organic acids (acetic acid, formic acid and oxalic acid) in ambient air precipitation - Ion chromatography
HJ 84-2016 Water quality determination of inorganic anions (F-, Cl-, NO2-, Br-, NO3-, PO43-, SO32-, SO42-)
HJ 549-2016 Determination of hydrogen chloride in ambient air and exhaust gas - Ion chromatography
HJ 669-2013 Water quality - Determination of phosphate - ion chromatography
HJ 544-2016 Determination of sulfuric acid fog in the exhaust gas of stationary sources - Ion chromatography
HJ 779-2015 Determination of hexavalent chromium in ambient air by post column derived ion chromatography
HJ/T 83-2001 Water quality - Determination of adsorbable organic halogens (AOX) by ion chromatography
HJ 769-2015 Determination of total sulfur in coal -- Escard-ion chromatography
GB 5009.256-2016 Determination of multiple phosphates in food for national safety
GB 5009.33-2016 Food national safety - Determination of nitrite and nitrate in food
GB 8538-2016 National Standard for Food safety Test method for drinking natural mineral water
GB/T 31197-2014 Determination of impurity anions in inorganic chemical products-ion chromatography
GB/T 30906-2014 - Determination of sodium tripolyphosphate content in sodium tripolyphosphate - Ion chromatography
GB/T 11446.7-2013 Test method for trace anions in electronic grade water by ion chromatography
GB/T 29400-2012 Determination of trace anions in chemical fertilizers - Ion chromatography
GB/T 3884.12-2010 Methods for chemical analysis of copper concentrates - Part 12: Determination of fluorine and chlorine content - ion chromatography
GB/T 6730.69-2010 Iron ore -- Determination of fluorine and chlorine -- ion chromatography
GB/T 24876-2010 Determination of seven anions in livestock and poultry breeding wastewater - Ion chromatography
GB/T 23978-2009 Liquid dyes -- Determination of chloride ion content -- ion chromatography
GB/T 15454-2009 Determination of sodium, ammonium, potassium, magnesium and calcium ions in industrial circulating cooling water -- ion chromatography
GB/T 23710-2009 Determination of betaine in feed - Ion chromatography
GB/T 20188-2006 Determination of bromate in wheat flour by ion chromatography
Determination of fluorine, chlorine, nitrite, nitrate and sulfate in atmospheric precipitation -- ion chromatography
GB/T 32953-2016 - Determination of melamine content in fertilizer - Ion chromatography
Standard method for health inspection of sulphates in the atmosphere of residential areas - ion chromatography

Main features
1) Flexible configuration, Canal-cation analysis system.
2) Independent detection and analysis system.
3) Only one station, one PC, saving space and cost.
4) Can be connected to automatic sampler, eluent generator.

2.Accurate temperature control
1) Precise temperature control system, fearless of ambient temperature changes. Temperature coefficient can be set, automatic compensation. Stable and fast, no long wait.
2) Wide target temperature setting range, excellent stability (conductance cell ±0.001ºC, column temperature box ±0.01ºC).

3.Large touch screen
1) 10.1 inch HD true color touch screen, integrated mirror glass design, wide field of vision, sensitive touch.
2) Parameter setting, spectrum viewing, status browsing, intuitive display, easy to operate.
3) Anti-misoperation design, parameter setting friendly reminder, convenient, not afraid of mistakes. Backlight brightness and time can be set.

4.Automatic range
1) Bipolar pulse detector, simple structure, stable.
2) Automatic range, wide range, no manual setting.

5.Pump, valve system
1) High pressure pump, PEEK material, 35MPa, 10mL/min, fine flow, stable, low noise.
2) Degassing pump, online degassing, free from bubble fluctuations.
3) peristaltic pump, can be used for cleaning, can also be used to replace the syringe sample.
3) Switch valve, shutdown is completely shut off the flow path to avoid micro-flow.

6Protection and alarm system
1) Upper and lower pressure detection, leakage detection, overheating detection, misoperation detection, fault detection.
2) Suppressor overvoltage, overcurrent detection, anti-dry burning detection.
3) Pump, valve, column, suppressor, eluent, use time long record.
4) Sound and light alarm.
5) Online filter, protect the column, easy to clean.
6) The eluent preheats the pipeline and pre-heats it before entering the column.
 
Provincial manual design
1) Automatic shutdown without manual presence. One key power on, one key power off, one key injection, one key upgrade, one key cleaning.
2) Recycling electrolytic regeneration suppressor, no need to configure regeneration liquid.
3) Mobile APP, remote browsing, remote operation.

8. PC chromatography workstation
1) New design, easy to use.
2) New fusion, chromatograph, automatic sampler, shower generator three in one.
 
Product Parameters
GA-P10D integrated ion chromatograph Single system ion chromatograph Analyzer Anion cationic tester
2. Main Technical Parameters
NO Name Model Qut unit Technical specification
1 Ion chromatograph GA-6210 1 Set Main engine, conductivity detector, PEEK pump, PEEK flow path, built-in column temperature box, conductivity cell, suppressor, U disk assembly.
2 Anionic column AS19(Thermelfeld brand ) 1 Set Fluorine, chlorine, sulfate, nitrate, nitrite, bromide, phosphate, chlorate, chlorite, bromate, dichloroacetic acid, trichloroacetic acid. (Imported from Thermo Fisher)
3 In-line degassing device MT-TQ 1 Set Remove air bubbles from the flow path
4 Online shower generator GA-6010B 1 Set Automatic generation of eluent, save labor, reduce error.
5 Automatic sampler GA-110 1 Set 108 stations
6 Anion protective column MT-N7 1 Set Protect the function of the column

 
Detailed Photos

Ga-8621anionic Scheme Ion Chromatograph Tester Pdhid Photoelectric Detection Equipment
Ga-8621anionic Scheme Ion Chromatograph Tester Pdhid Photoelectric Detection Equipment

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier