ISO 8301 ASTM C518 Protective plate heat flux meter method Thermal conductivity tester

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 year
Still deciding? Get samples of US$ 3000/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (7)
  • ISO 8301 ASTM C518 Protective plate heat flux meter method Thermal conductivity tester
  • ISO 8301 ASTM C518 Protective plate heat flux meter method Thermal conductivity tester
  • ISO 8301 ASTM C518 Protective plate heat flux meter method Thermal conductivity tester
  • ISO 8301 ASTM C518 Protective plate heat flux meter method Thermal conductivity tester
  • ISO 8301 ASTM C518 Protective plate heat flux meter method Thermal conductivity tester
  • ISO 8301 ASTM C518 Protective plate heat flux meter method Thermal conductivity tester
Find Similar Products
  • Overview
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
GA-RP-301
Weight
173kg
Power Source
AC220V
pressure range
0-1000N
resolution
0.1N
Transport Package
Plywood Case
Specification
750*640*1720mm
Trademark
GONOAVA
Origin
China
HS Code
9024800000
Production Capacity
200

Product Description

GA-RP-301 Protective plate heat flux meter method Thermal conductivity tester ISO 8301 ASTM C518
1.Product introduction

The instrument adopts the internationally popular method of heat flux meter to detect thermal conductivity and thermal resistance, and is equipped with computer to realize automatic detection and generate experimental report. It is suitable for the thermal conductivity test of concrete, thermal insulation cotton, foam materials, thermal insulation materials, refractory materials and other low thermal conductivity materials. With sample frame, it can be used for powder material detection. It is widely used in colleges and universities, scientific research institutes, quality inspection, factories and mines.
Reference standards of this instrument: JIS-1412-2 Thermal resistance and thermal conductivity determination method of hot edge materials, GB/T10295-2008, ISO 8301: 1991 (Determination of Steady-State Thermal Resistance and Related Properties of adiabatic Materials by Heat flux meter method) and ASTM C518-04 Test method for Determination of steady-State heat flux and Heat Transfer Characteristics by heat flux meter method.
Ii. System composition:
a) Hot surface heater, high precision programmable meter temperature control, hot surface temperature resolution of 0.01ºC,
b) The cold side adopts constant temperature water tank temperature control, the fluctuation is less than 0.05 degrees, and the cold side temperature measurement resolution is 0.01 ° C.
c) The installation of protective measurement and control devices can effectively eliminate the impact of the environment on the test and ensure the test accuracy and repeatability.
D) Equipped with automatic pressure, automatic thickness measurement function, can detect the thermal conductivity under different pressures.
Product Parameters
GA-RP-301 Protective plate heat flux meter method Thermal conductivity tester ISO 8301 ASTM C518
2. Product Parameter

1. thermal conductivity range and accuracy: 0.0010 ~ 3.0000W/m k, retain 4 decimal places;

2. measurement accuracy: ≤±3%, repeatability: ±1%,
3. sample size: 300×300 (mm), thickness 10-50mm. Special sizes can be customized.
4. can test solid materials, powder materials.
5. hot surface temperature and control: room temperature ~140ºC (customized), plate heater, bidirectional thyristor control, temperature resolution 0.01ºC.
6. cold surface temperature and control: 5~90ºC, the cold surface is controlled by a constant temperature sink to ensure that the cold surface temperature is stable (precision constant temperature sink, temperature adjustable), temperature resolution of 0.01ºC, temperature accuracy of 0.05ºC.
7. the sample is loaded by decelerating motor, and connected to the computer control accurate pressure clamping, pressure range 0-1000N, resolution 0.1N.
8. the use of high-precision displacement sensor measurement sample thickness, and connected to the computer automatic measurement, 0-50mm, resolution 0.01mm.
9. the test part with transparent plexiglass wind hood, side door, you can see the test situation in the instrument.
10.the installation of protective measurement and control device, can effectively eliminate the impact of the environment on the test, to ensure the test accuracy and repeatability.
11. voltage: 220V,50HZ.
3. the complete set of instruments
GA-RP-301Thermal conductivity tester host  1set
 
Test software (including communication interface)  1set
 
Communication interface and data line    1set
 
Communication interface and data line    1set
 
Computer 1set
 
Package size and weight:  
GA-RP-301 host           750*640*1720mm, 173kg
Thermostatic water tank   490*410*750mm ,35Kg.
 
Detailed Photos

 

ISO 8301 ASTM C518 Protective plate heat flux meter method Thermal conductivity testerISO 8301 ASTM C518 Protective plate heat flux meter method Thermal conductivity tester
ISO 8301 ASTM C518 Protective plate heat flux meter method Thermal conductivity tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier