DSY-II Carbon (Graphite) Air Permeability Tester air tester Air Leak Detector

Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 year
Still deciding? Get samples of US$ 1000/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (7)
  • DSY-II Carbon (Graphite) Air Permeability Tester air tester Air Leak Detector
  • DSY-II Carbon (Graphite) Air Permeability Tester air tester Air Leak Detector
  • DSY-II Carbon (Graphite) Air Permeability Tester air tester Air Leak Detector
  • DSY-II Carbon (Graphite) Air Permeability Tester air tester Air Leak Detector
  • DSY-II Carbon (Graphite) Air Permeability Tester air tester Air Leak Detector
  • DSY-II Carbon (Graphite) Air Permeability Tester air tester Air Leak Detector
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
DSY-II
Weight
0-100Kg
Transport Package
Plywood Case
Trademark
GONOAVA
Origin
China
HS Code
9024800000
Production Capacity
200

Product Description

Product Description

DSY-II Carbon (Graphite) Air Permeability Tester air tester Air Leak Detector

           This instrument is used to measure the permeability coefficient (i.e. air permeability) of carbon materials based on GB/T9973-2006 Carbon Materials Air Permeability Test Method.

The permeability coefficient of carbon materials refers to the permeability coefficient calculated by measuring the decay rate of the vacuum degree in the sample in the air.

1. Instruments and equipment
 Vacuum test device: Use a vacuum pump to extract the air from the sample. 2. Sample fixture: The sample fixture should ensure that the gas can only pass through the pores of the sample without leaking from the edge of the sample.

2. Sample preparation
       1. The two bottom surfaces of the sample must be parallel. The surface of the specimen shall be free of cracks, blisters and obvious uneven defects.

The surface of the specimen must be cleaned of dust and debris and dried at 110°C for 2 hours.

        2. Each group shall have no less than two specimens.

3. Test steps
    Put the sample into the corresponding fixture, seal both ends with silicone pads, and tighten with bolts to ensure the sealing of both ends. Then turn on the "power switch", open the vacuum valve, close the "inlet valve", and start the vacuum pump. Then open the computer software and click "Test". When the computer data shows normal, click "Stop" and click "Enter System" to enter the test interface. Enter the height value and inner hollow diameter of the sample, set the test time, and the time interval for collecting data. When the air inside the sample reaches vacuum, close the "vacuum" valve, stop the vacuum pump, click "Start Test", and the computer will automatically time the test. When the set time is reached, the test will end. Click "Save Data" and "Generate Report". Open the "air inlet valve" to take out the sample.

Product Parameters

DSY-II Carbon (Graphite) Air Permeability Tester air tester Air Leak Detector
2.
Calculation of results


Calculate the sample permeability coefficient according to the following formula.

For cylindrical specimens:

                             dp·v·L
                  K = -----------
                       dt·A·△P

            V--Void volume inside the sample (mm);

            L--sample height (mm);

            A--effective area of air passing through the sample (mm2);

           dp/dt - pressure increase rate per unit time (MPa/s);

             △P--Air pressure (0.1MP);
 

If the difference in K values
obtained from two measurements of the same sample is ≤5%, their average value shall be used as the test result.

Take their average value as the final test result. Otherwise, the actual measurement results will be reported.

Detailed Photos
DSY-II Carbon (Graphite) Air Permeability Tester air tester Air Leak Detector

DSY-II Carbon (Graphite) Air Permeability Tester air tester Air Leak Detector
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier