Customization: | Available |
---|---|
After-sales Service: | Online |
Warranty: | 1 year |
Still deciding? Get samples of US$ 3700/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Surveying and mapping APP |
Use the APP to cooperate with the receiver to realize the GPS pipeline surveying and mapping function, realize positioning measurement, management and view the geographical coordinates, depth and other information of underground pipelines, and provide cloud services for data storage, backup, transfer, etc. |
Troubleshooting and positioning | Together with the A-frame, it can accurately locate cable ground faults. |
RTK | Use RTK equipment to achieve centimeter-level high-precision positioning function, and use a dedicated APP with a handheld device to achieve precise point-determining mapping of pipeline locations. |
Function | Pipeline detection (cable position tracking, direction display, depth measurement, current measurement), live cable identification, power outage cable identification, pipeline ground fault finding, ground resistance test, external voltage test |
power supply | 7.4V DC 2600mAh rechargeable lithium-ion battery pack |
Input method | Built-in receiving coil, flexible caliper, stethoscope, alligator clip test lead (voltage test) |
Bluetooth communication | Supports Bluetooth communication for instrument control and connection to mobile APP for various data processing |
receiving frequency | Active detection frequency: 577Hz, 640Hz, 1280Hz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10kHz, 33kHz, 66kHz, 82kHz, 201kHz |
Pipe detection mode | Broad peak method, narrow peak method, sound valley method |
Pipeline detection display | Classic positioning mode, wire cruise mode, signal curve mode |
Pipeline detection Detection range |
Direct connection method: Generally, the cable length can be 0~20 kilometers, which is mainly determined by the ground resistance, cable resistance and cable burial depth. |
Dept and current | Automatic reading of cable depth and current values |
Pipeline measurement depth | 0~20m |
Depth accuracy | Plane position precise positioning accuracy: The center axis position of the target cable or pipeline: |
Right or wrong tips | Eliminate interference from adjacent cables. When measuring adjacent cables, the measurements of adjacent cables can be distinguished based on the different signal strengths fed back by adjacent cables and the phase of the measured current. During the process of tracking the cable, observe the phase dial and pointer pointing to distinguish the cable under test. and adjacent cables |
Sound instructions | FM tones that vary with signal strength |
Anti-interference ability | Extremely narrow receiving frequency band and unique digital processing method can fully suppress power frequency and harmonic interference from nearby running cables and pipelines |
Interference distance | When using the coupling method and the induction method, the transmitter will produce interference at a short distance. The interference distance is related to the transmission power and frequency. The greater the power and the higher the frequency, the stronger the interference. |
Cable identification | Identification method: flexible caliper intelligent identification, stethoscope identification; |
Cable identification Detection range |
Number of calibrated cables: 1 to 10; |
Ground resistance | Test range: 0.001Ω~2000Ω |
Voltage measurement | Test method: Precision 4-wire method measurement |
LED night lighting | Receiver has LED flashlight function |
liquid crystal | 3.5-inch color screen LCD |
size | Approximately 290mm (length)×128mm (width)×700mm (height) |
quality | About 1.90kg |
charger | DC 8.4V 1A |
Lighting power | 1Wmax |
Connection interface | 1*mini-B USB interface (for firmware upgrade) 1*DC charging port 1*Flexible caliper connection socket 2*External voltage test line connection interface 4*Ground resistance test line connection interface |
Flexible current clamp | Approximately 620mm long, approximately 8mm wire diameter |
Coil inner diameter | φ200mm (larger diameter can be customized as needed) |
stethoscope size | Length, width and thickness are about 111mm×60mm×27mm (stethoscope optional) |
Lead length | Stethoscope lead length: about 3m |
test line | 1*Red test line 5m 1*yellow test line 3m 1*green test line 3m 1*Black test line 3m |
Working temperature and humidity | -10ºC~40ºC; below 80%Rh |
Storage temperature and humidity | -10ºC~50ºC; ≤95%RH, no condensation |
Pressure resistant | AC3700V/rms (between the upper and lower ends of the housing) |
Suitable for safety regulations | IEC61010-1 CAT 600V, IEC61010-031, IEC61326, pollution level 2 |
Function | Multiple frequency signal transmission methods, insulation resistance test |
power supply | 11.1V DC 12800mAh rechargeable lithium-ion battery pack |
Output mode | Direct connection method, caliper coupling method, induction method |
Output frequency | 577Hz, 640Hz, 1280Hz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10kHz, 33kHz, 66kHz, 82kHz, 201kHz |
Output power | 10W max, 10 levels adjustable |
Impedance | Fully automatic real-time impedance matching and protection functions |
Direct connection output voltage | 150Vpp max |
circuit protection | With overload and short circuit protection |
Insulation resistance Test voltage |
100V,250V,500V,1000V,2500V |
Insulation resistance Measuring range and accuracy |
0.01MΩ~25.0GΩ ±3%rdg ±5dgt 25.0GΩ~2.5TΩ ±15%rdg ±5dgt |
liquid crystal | 5.6-inch LCD color screen |
Instrument size | About 320mm (length) × 275mm (width) × 145mm (height) |
quality | The transmitter is about 3.85kg; the transmitter clamp is about 1.18kg |
charger | DC 12.6V 2A |
Launch clamp size | Length, width and thickness 297mm×194mm×39mm |
Launch clamp inner diameter | φ150mm |
Launch clamp wire length | 3m |
test line | Red test line 5m, green test line 3m, black test line 3m |
Connection interface | 1*Type-B USB interface (for firmware upgrade) 1*DC charging port 1*Signal transmitter clamp connection socket 2*direct test line interface 3*Insulation resistance test line interface |
Resistant to pressure | The transmitter adopts an integrated special tool box design, and the box can withstand a pressure of about 200kg. |
Pressure resistant | AC 3700V/rms (between the top and bottom of the instrument box) |
Electromagnetic properties | IEC61326(EMC) |
Suitable for safety regulations | IEC61010-1 (CAT III 300V, CAT IV 150V, pollution level 2) |