Surface Area and Pore Size Analyzer Pore Size Measurement Instrument Surface Area Analyzer

Product Details
Customization: Available
After-sales Service: online
Warranty: 1 year
Still deciding? Get samples of US$ 200/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (7)
  • Surface Area and Pore Size Analyzer Pore Size Measurement Instrument Surface Area Analyzer
  • Surface Area and Pore Size Analyzer Pore Size Measurement Instrument Surface Area Analyzer
  • Surface Area and Pore Size Analyzer Pore Size Measurement Instrument Surface Area Analyzer
  • Surface Area and Pore Size Analyzer Pore Size Measurement Instrument Surface Area Analyzer
  • Surface Area and Pore Size Analyzer Pore Size Measurement Instrument Surface Area Analyzer
  • Surface Area and Pore Size Analyzer Pore Size Measurement Instrument Surface Area Analyzer
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Our Advantages
Overview

Basic Info.

Model NO.
GA-100
Specification
400*300*160(mm)
Trademark
GONOAVA
Origin
Changsha
HS Code
9024800000
Production Capacity
200

Product Description

Product Description

Surface Area and Pore Size Analyzer Pore Size Measurement Instrument Surface Area Analyzer 
1.Product introduction

The GA 100 Series can accurately produce surface area and pore size results of powder materials. According to the different test functions, this series of instruments are divided into three types, there are A, B, and C, the C type is configured with 1 torr or 0.1 torr high-sensitive pressure sensors and turbo molecular pump with ultimate pressure of 10¯8 Pa, it can effectively take microporous analysis of microporous materials such as molecular sieve, catalyst, activated carbon, and other microporous materials.
Surface Area and Pore Size Analyzer Pore Size Measurement Instrument Surface Area Analyzer

Surface Area and Pore Size Analyzer Pore Size Measurement Instrument Surface Area Analyzer 
2.Features
  • Test Module
  • Internal temperature of test module can be controlled through Real-time monitoring, ensuring accuracy of adsorption detection.
  • Saturated Vapor Pressure P0
  • Using independent P0 pressure sensor for P0
    value by inching test, guarantees the reliability of experimental data. Atmospheric pressure input method to determine P0 also be selected.
    Pressure Sensor
    Mico 100Cwith 1torr (selectable 0.1torr) makes the partial pressure of P/P0up to 10-7 -10-8(N2/77K) in the physical adsorption analysis.
  • Vacuum System
  • It's a multi-channel, adjustable, andparallel vacuum system. Vacuum degree of this system can be controlled in segments.
    This design prevents the sample from being pumped into analyzer. Meanwhile, a delicate part was designed for ensuring cleanliness of vacuum system, minimizing dust pollution.
  • Sample Preparation System
  • In addition to two pretreatment stations, the other two analysis stations can be used in preparing samples.There is no interference between pretreatment stations and analysis .
    stations. Degas temperature can be set individuallyand controlled from ambient to 400 oC.
  • old Free Space
  • Cold free space can be corrected by Helium automatically, ensuring accuracy of test results. This calibration method is suitable for testing of any
    powderor particle material.
  • Control of Liquid Nitrogen level
  • Using High volume (3L) Dewar flasks and working with the seal cover assure a constant thermal profile along the length of sample tubes and P0 tubes throughout testing process.
    Turbo Molecular Pump
    Molecular pump is a standard configuration part on the Micro 100C. The ultimate pressure is up to 10-8 Pa, providing a strong support for micropore analysis in the ultra-low pressure. The smallest micro-pore diameter can be tested is 0.35 nm.
  • Sample Preparation System
  • In addition to two pretreatment stations, the other two analysis stations can be used in preparing samples. There is no interference between pretreatment stations and analysis stations.
    Degas temperature can be set individually and controlled from ambient to 400 degree centigrade
  • Micropore Distribution
  • Accurately apply the HK method, SF method and other micropore analysis model, the aperture deviation of micropore is less than 0.02 nm.
  • Surface Area and Pore Size Analyzer Pore Size Measurement Instrument Surface Area Analyzer 
  • 3. PAS Control and Analysis Software
  • PAS Software is intelligent software in operation control, data acquisition, calculation and analysis and report generation on the Windows platform. This software can communicate with the host through the LAN port and remotely control many instruments at the same time.
  • PAS Software adopts a unique intake control method, the pressure in adsorption and desorption process is optimally set in six- stage; this flexible design is helpful for improving test efficiency.
  • Changes of the pressure and temperature inside the manifold can be observed directly in the test interface which is convenient for sample test and instrument maintenance.
  • Current state of analyzer can be intuitively understood with the indicator light and event bar.
  • Each adsorption equilibrium process is dynamically displayed on the test interface. Adsorption characteristics of the sample can be easily understood.
Product Parameters

Surface Area and Pore Size Analyzer Pore Size Measurement Instrument Surface Area Analyzer 
4. Technical Parameter 
Type GA-100A GA-100B GA100C
Adsorbed Gas Non corrosive gases, such as N2, Ar, Kr, H2, O2, CO2, CO, NH3, CH4, etc.
Pressure Sensor at Analysis Station 1000 torr 1000 torr,10 torr 1000 torr, 10 torr, 1 torr (optional 0.1 torr)
Accuracy: ±0.15% (F.S.)
Pressure Sensor at P0 Station 1000 torr
(Accuracy: ±0.15% (F.S.)
Degas System
 
2 ectopic vacuum heating degas station;
Samples on analysis bits can be degassed simultaneously.
Degas Temperature Ambient to 400 oC. Free to set up target temperature.
Cold Trap 1
Vacuum Pump
 
Two-stage rotary vane mechanical vacuum pump, the ultimate vacuum is 6.7*10-2 Pa
 
Turbo molecular pump (ultimate vacuum
10-8 Pa) and front mechanical
 vacuum pump
Analysis Port Samples on the 2 analysis bits can be tested alternately (including P0 test).
Test Principle Gas adsorption by static-volumetric analysis
Measurement Range of
Specific Surface Area
0.0005 m2/g to the infinity;
Standard sample repetition is less than ± 1.0%
 
0.0001 m2/g to the infinity;
Standard sample repetition is less than ± 1.0%
Test Range of Pore Diameter
 
0.35 nm-500 nm;
Repeatability of pore size is less than 0.2 nm in the accurate analysis of porous materials which size is more than 2 nm
0.35 nm-500 nm;
Repeatability of pore size is less than 0.2 nm in the accurate analysis 0.7 nm-2 nm micropore.
0.35 nm-500 nm;
Repeatability of pore size is less than 0.2 nm in the accurate analysis 0.35 nm-2 nm
micropore.
Minimum Pore Volume 0.0001 cm3/g
Range of Relative Pressure P/P0  10-5-0.998
 
10-6-0.998
 
10-8-0.998
 
Overall Dimension Depth: 870 mm; width: 570 mm; height: 890 mm; weight: 80 Kg -90 Kg
Ambient Temperature 15-40 oC
 
Related Humidity 30%-60%
Electrical Supply AC220 V ± 20 V, 50/60 HZ, maximum power 300W;
5.Applications
Applied Field Typical Materials Details
Material Research ceramic powder, metal powder, nanotube According to surface area value of nanotube, hydrogen storage capacity can be predicted.
Chemical Engineering carbon black, amorphous silica, zinc oxide, titanium dioxide Introduction of carbon black in rubber matrix can improve mechanical properties of rubber products.
Surface area of carbon black is one of the important factors affecting the reinforcement performance of rubber products.
New Energy lithium cobalt, lithium manganate Increasing surface area of electrode can improve Electrochemical reaction rate and promote iron exchange in negative electrode.
Catalytic Technologies active alumina oxide, molecular sieve, zeolite Active surface area and pore structure influence reaction rate.
Detailed Photos

 

Surface Area and Pore Size Analyzer Pore Size Measurement Instrument Surface Area Analyzer
Our Advantages


Surface Area and Pore Size Analyzer Pore Size Measurement Instrument Surface Area Analyzer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier