GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)

Hunan Gonoava Instrument Co Ltd
  • Audited Supplier
  • 3 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Automated Testing Process: Microcomputer automatically detects, calculates, and controls the test without personnel on duty.
  • Dual Sample Testing: Capable of testing two groups of oil samples simultaneously for increased efficiency.
  • High Precision Sensors: Equipped with imported high-precision pressure sensors and transmitters for accurate readings.
  • Real-time Data Monitoring: Touch screen displays real-time pressure, curves, and allows historical data query and comparison.
  • Safety Features: Includes real-time oil and gas recovery device and automatic leakage detection for safety.
  • Stable Rotation System: Imported rotating device with stainless steel construction ensures stable speed and low noise.
  • 1-Year Warranty: Comes with a comprehensive 1-year warranty for peace of mind.

Product Images of GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)

GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method) pictures & photos
GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method) pictures & photos
GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method) pictures & photos
GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method) pictures & photos
GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method) pictures & photos
GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method) pictures & photos
GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
  • GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
    GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
  • GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
    GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
  • GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
    GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
  • GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
    GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
  • GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
    GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
  • GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
    GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)

Find Similar Products

Product Description

GA-H311 ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
Conforms to standard: SH/T0193 ASTM D2272
Scope of application: This standard uses an oxygen pressure vessel (oxygen bomb) to evaluate the oxidation stability of new and used turbine oils with the same composition (base oil and additives) at 150°C in the presence of oxygen and copper catalyst.

Performance characteristics:
The instrument adopts advanced foreign technology, and the microcomputer automatically detects, calculates and controls. No personnel are required to be on duty during the entire test process, and the degree of automation is high. Real-time communication with the host computer, the connection method is simple and reliable. The temperature and pressure can be calibrated at any time to ensure the accuracy of pressure and temperature. Automatically record the data and test results during the test. The past records can be queried, compared, and the pressure change curve can be printed out. Automatically determine the pressure inflection point and automatically end the test. Imported rotating device, stable speed and low noise. Two groups of oil samples can be tested at the same time. The oxygen bomb is equipped with a free-direction rotating transmitter, which can accurately transmit signals in real time to ensure long service life; it is equipped with a stainless steel rotating device to ensure real-time and stable rotation; the instrument is controlled by a touch screen, which is easy to operate and can display real-time pressure and curves, and calculate the final results; users can find historical data and calculate results; it is equipped with a real-time oil and gas recovery device to reduce the damage of oil and gas to experimenters; it can automatically maintain temperature in real time, automatically fill and release oxygen, automatically judge leakage, automatically judge the test inflection point, and automatically cut off heating after the test is completed; it is equipped with imported high-precision pressure sensors and pressure transmitters.

GA-H311 ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
Main parameters:
Power supply AC220V±10%, 50Hz
Heating power ≤2800W
Temperature control range room temperature ~ 200ºC
Temperature control accuracy ±0.1ºC Digital precision pressure
Sensor accuracy ±2‰
Motor speed 105±5r/min
Printing motor thermal type
Pressure range 0-1500KPa
Pressure accuracy  ±2‰
Oil bath temperature control point 0-200ºC adjustable
Oil bath temperature control accuracy  ±0.1ºC
Test bomb 2 sets
Dimensions 600×750×850


GA-H311 ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)GA-H311ASTM D2272 Automatic Lubricating Oil Oxidation Stability Tester (Rotating Oxygen Bomb Method)
 


 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASI249867". Items marked "verified" are certified.

Watch Video
Watch Video
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd

About Our Factory & Business Background

verified Business Type
Trading Company
Address
Room 2318, Building 29 Yingyuewan, Runhe Yicheng Yueliangdao Street, Wangcheng, Changsha, Hunan, China
verified Plant Area
120 square meters
verified Number of Employees
8
verified Terms of Payment
T/T, LC, D/P, PayPal, Small-amount payment, Western Union
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port
verified Minimum Order Quantity
1 Piece
verified Supply Chain Partners
9

Our Production Capability & Technical Expertise

verified Main Products
Differential Scanning Calorimeter; Gas Chromatograph; Vacuum Type Dilatometer; Tensile Strength Tester
verified Customization Options
Customization from Samples
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2023-04-06
verified Export Year
1 Year
verified Main Markets
North America, Southeast Asia/ Mideast, East Asia(Japan/ South Korea)
verified Repeat Buyers Choice
< 10%
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
No

Our Certifications, Standards & Industry Recognition

verified Cooperated with Fortune 500
No

FAQ

What standards does this tester conform to?
The GA-H311 conforms to SH/T0193 and ASTM D2272 standards for evaluating oxidation stability.
Can this device test new and used oils?
Yes, it evaluates the oxidation stability of both new and used turbine oils with the same composition.
How many samples can be tested at once?
The instrument is designed to test two groups of oil samples simultaneously.
Is the test process fully automated?
Yes, it automatically records data, determines inflection points, ends the test, and cuts off heating.
What is the minimum order quantity?
The minimum order quantity is 1 piece.
What are the available payment terms?
We accept T/T, LC, D/P, PayPal, small-amount payment, and Western Union.
How long is the lead time for delivery?
The average lead time is within 15 workdays for both peak and off-peak seasons.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Product Groups

Product Catalogs