1. Reference standard
B-T 10259-2014 Water blocking tape for electrical and optical cables;
Water-blocking Tape optical cables Surface Volume Resistivity Tester
2. Scope of use
Surface resistance: The quotient of the voltage applied between two electrodes on a certain surface of the sample and the current flowing between the two electrodes after a certain period of time. The surface resistance test of the water-blocking tape is carried out according to the method in Appendix C.
Volume resistance: The quotient of the DC voltage between two electrodes placed on two opposite surfaces of the sample and the stable current flowing between the two electrodes.
Volume resistivity: The quotient of the DC electric field strength in the material and the stable current density. The volume resistivity test of the water-blocking tape is carried out according to the method in Appendix D; the test temperature is 23ºC±2ºC.
Water-blocking Tape optical cables Surface Volume Resistivity Tester
3. Function introduction
Adopt LCD display, digital key operation, Chinese or English operation interface; with 232 and USB communication ports; optional PC software report export and data management
Model | FT-3030G |
1. Resistance measurement range | 10^3Ω~1×10^12Ω |
2. Resistivity measurement range | 10^3~ 2.0×10^12Ω-cm |
3. Test voltage | 0-500V |
4. Basic accuracy | ±2% |
5. LCD display | Resistivity, resistance, temperature, current, voltage, test sample data can be input |
6. Operating environment | Temperature: 0ºC~40ºC, relative humidity <80% |
7. Power supply | AC 220V,50HZ, 5W |
8. Measurement mode | Configure 232 and USB communication interfaces, LCD display test or PC software test |
9. Electrode fixture | The configuration standard requires one set of surface resistance and one set of volume resistance fixtures |
10. PC software (optional) | PC Test Software |
11. Dimensions | L 340mm* W 320mm* H 120mm |