Microcomputer Carbon and Hydrogen Analyzer GA-304

Product Details
Customization: Available
After-sales Service: online
Warranty: 1 year
Still deciding? Get samples of US$ 4000/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (7)
  • Microcomputer Carbon and Hydrogen Analyzer GA-304
  • Microcomputer Carbon and Hydrogen Analyzer GA-304
  • Microcomputer Carbon and Hydrogen Analyzer GA-304
  • Microcomputer Carbon and Hydrogen Analyzer GA-304
  • Microcomputer Carbon and Hydrogen Analyzer GA-304
  • Microcomputer Carbon and Hydrogen Analyzer GA-304
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Our Advantages
Overview

Basic Info.

Model NO.
GA-304
Transport Package
Plywood
Specification
81*40*41*(cm)
Trademark
GONOAVA
Origin
Changsha
HS Code
9024800000
Production Capacity
200

Product Description

Product Description

Microcomputer Carbon and Hydrogen Analyzer GA-304 

Introduction
Microcomputer Carbon and Hydrogen Analyzer surpasses the requirements of the national standard GB/T 476-2008 "Method for the Determination of Carbon and Hydrogen in Coal by Coulometric-Gravimetric Method." The instrument uses coulometric method for hydrogen measurement and gravimetric method for carbon measurement, with computer operation and data processing, ensuring high accuracy. It is used for determining the content of carbon and hydrogen in coal, crude oil, and other solid materials, making it a coal quality analysis instrument suitable for the conditions of our country. The instrument can analyze special samples using various methods, and it can save data in real-time and retrieve historical data. The method for the determination of carbon and hydrogen in coal, GB/T 476-2008, has replaced GB/T 476-2001 and GB/T 15460-2003.

Features

The entire analysis process is controlled by a computer, with a high degree of automation.
The operation interface is intuitive and convenient, with a liquid crystal display showing the electrolysis peak shape, and analysis results are output through a color printer.
The weight data of the carbon tube can be directly input into the computer, which automatically calculates the carbon content and synthesizes a data report together with the hydrogen content (in a format according to customer requirements).
Advanced cleaning technology is used for the electrolytic cell, eliminating the previous cumbersome cleaning process and extending the service life of the electrolytic cell.
The system is equipped with a built-in electrolytic cell recirculating water cooling device, which is convenient to use.
The computer program controls the automatic coating of the electrolytic cell. The percentage content is automatically displayed, and the measurement results are accurate.

Standard

Advanced cleaning technology for the electrolytic cell, eliminating the previous cumbersome cleaning process and extending the service life of the electrolytic cell.
The system is equipped with an automatic cooling device for the electrolytic cell, which is convenient to use.
The system has an automatic coating function for the electrolytic cell.
Optimized system settings, after the weight data of the carbon tube is input into the computer, the data processing for carbon and hydrogen is automatically carried out.
Suitable for the determination of carbon and hydrogen content in a variety of materials such as coal, coal slag, coke, minerals, rocks, and petrochemical products.
 
Microcomputer Carbon and Hydrogen Analyzer GA-304 
Product Parameters
 
Specification Details
Measurement Range Carbon: 1~99% Hydrogen: 0.05~99.9%
Temperature Control Range Combustion furnace: Room temperature to 1100°C
  Conversion furnace: Room temperature to 500°C
Temperature Accuracy <±5°C
Coating Voltage 10V ± 0.5V
Operating Voltage 24V ± 0.5V
Accuracy Complies with GB/T 476 standards
Repeatability Error Carbon: ≤0.50%
  Hydrogen: ≤0.15%
Power 1500W
Main Unit Dimensions 820(L) * 400(W) * 410(H) mm
Microcomputer Carbon and Hydrogen Analyzer GA-304 
Detailed Photos

Microcomputer Carbon and Hydrogen Analyzer GA-304Microcomputer Carbon and Hydrogen Analyzer GA-304Microcomputer Carbon and Hydrogen Analyzer GA-304Microcomputer Carbon and Hydrogen Analyzer GA-304Microcomputer Carbon and Hydrogen Analyzer GA-304Microcomputer Carbon and Hydrogen Analyzer GA-304 
Our Advantages
 




 

Microcomputer Carbon and Hydrogen Analyzer GA-304

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier