CRH-V vacuum glass heat transfer coefficient tester Vacuum glass thermal conductivity meter
1.Product introduction
The instrument mainly measures the vacuum glass heat transfer coefficient U(K) value test, in line with the standard JC/T2708-2022 "vacuum glass heat transfer coefficient detection method". It can also test plastic, rubber, glass, fiber, benzene board, extrusion board, fostered concrete, hollow glass, wood, all kinds of thermal insulation materials and other uniform plate materials, and can measure the thermal conductivity of granular materials, bulk materials, soft materials and other substances. Applicable standard: GB/T10294-2008 "Determination of steady-state thermal resistance and related characteristics of thermal insulation materials"; GB/T3399-1982 "plastic thermal conductivity test method - heat protection plate method"; GB/T10801.1-2002 "Polystyrene foam for thermal insulation" specified in the measurement of thermal conductivity of polyurethane rigid foam materials; GB/T10801.2-2002 "Extruded polystyrene foam for insulation (XPS)" specified in the extruded polystyrene foam thermal conductivity measurement; GB/T3139-2005 "fiber reinforced plastics thermal conductivity test method"; GB/T 17794-2008 "Flexible foam rubber insulation products".
Product Parameters
CRH-V vacuum glass heat transfer coefficient tester Vacuum glass thermal conductivity meter
2. Product Parameter
heat transfer coefficient U(k) measurement range
|
0.5 ~ 30 W/ .k
|
thermal conductivity measurement range
|
0.001 ~ 3.000 W/ m.K |
measurement accuracy
|
±3% |
Hot surface temperature measurement range
|
room temperature ~ 159ºC, temperature resolution: 0.01ºC |
Cold surface temperature measurement range
|
0 ~ 60ºC, temperature resolution: 0.01ºC |
pressure measurement range
|
0 ~ 1000N, resolution: 0.1N
|
Test piece size
|
300*300* (5 ~ 50) mm (basic configuration) (other specifications can be customized according to user requirements) |
power supply power |
220V 50HZ.500W |
full computer automatic detection and data processing system, compatible with the general computer.
3. complete set
1. One host computer;
2. A set of analysis software (Chinese and English versions);
3, HX-1005 precision low temperature constant temperature tank one (temperature control accuracy 0.01ºC);
4, a desktop Lenovo computer (users can choose);
5. A standard sample;
4. Dimensions and weight
1. Host: standard landing model: (length × width × height) 550×450×1500mm, net weight: 100Kg.
2, precision low temperature constant temperature tank: (length × width × height) 300×350×530mm, net weight: 35Kg.