ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence Edxrf X-ray Fluorescence Spectrometer Sulphur Testing

Product Details
Customization: Available
After-sales Service: Online
Application: Laboratory Apparatus
Still deciding? Get samples of US$ 5000/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (7)
  • ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence Edxrf X-ray Fluorescence Spectrometer Sulphur Testing
  • ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence Edxrf X-ray Fluorescence Spectrometer Sulphur Testing
  • ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence Edxrf X-ray Fluorescence Spectrometer Sulphur Testing
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Our Advantages
Overview

Basic Info.

Model NO.
GA-D1262
Warranty
1 Year
Detection Method
Spectrophotometer
Advantage
High Sensitive
Principle
New Spectrometer
Light Number
Monochromator
Customized
Customized
Transport Package
Plywood Case
Specification
540mm× 500mm× 450mm
Trademark
GONOAVA
Origin
Changsha
HS Code
9024800000
Production Capacity
200

Product Description

Product Description

ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence EDXRF X-ray Fluorescence Spectrometer Sulphur Testing 

Low detection limit (300s) (atmospheric): 2.6ppm.
Weight only (including battery, printer): 5.6kg.
Specially suitable for on-site rapid detection and analysis

Improved to meet the 2019 version of GB/T 17040.
Meets the low sulfur detection standards for national IV gasoline and diesel, and marine fuel oil for near-sea and ocean-going vessels.

Technology
Energy Dispersive X-ray Fluorescence (EDXRF) analysis technology
Low background thin beryllium window proportional counter, secondary filter
Reasonable combination of high voltage, current, and target material for X-ray source

ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence EDXRF X-ray Fluorescence Spectrometer Sulphur Testing 

Complies with standards:
GB/T 17040
GB 17411
ASTM D4294

Overview

The X-ray fluorescence sulfur analyzer is a quantitative analysis instrument used in industries such as petroleum, coal, building materials, metallurgy, and mining, primarily for measuring the total sulfur (S) content in materials like petroleum and its products, coal, cement, and carbon black. Due to its use of a physical analysis method, it features fast analysis speed, no need for complex sample pretreatment, high precision, minimal human error, low labor intensity for operators, and no pollution, hence it has been widely applied and has essentially replaced chemical analysis methods.
The GA-1262 model Energy Dispersive X-ray Fluorescence (EDXRF) portable sulfur analyzer, also known as the GA-1262 EDXRF portable sulfur analyzer, is developed by our company based on decades of research experience in X-ray fluorescence analyzers. It is an improvement upon the GA-1260 model, which has already sold over a thousand units. Like the DM1260, it employs Energy Dispersive X-ray Fluorescence (EDXRF) analysis technology, a compact X-ray tube as the excitation source, a thin beryllium window gas-filled proportional counter, secondary filters, and a special optical path system. It features automatic C/H ratio correction, suitability for various samples, integration, large data storage capacity, and fast and accurate analysis. 
ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence Edxrf X-ray Fluorescence Spectrometer Sulphur Testing
 
Figure 0. Principle Diagram of EDXRF Analysis Technology

The GA-1262 model EDXRF portable sulfur analyzer has been improved and launched to meet the on-site rapid detection and analysis of sulfur content in oil products and the 2019 version of GB/T17040. In addition to retaining the advantages of the original GA-1260, the following significant improvements have been made:
(1) A proportional counter with a lower background and thinner window has replaced the original proportional counter. The distances and angles between the radiation source, detector, and sample have been adjusted. The thickness of the secondary filter has also been adjusted.
(2) An adjustable X-ray source has replaced the fixed X-ray source, allowing for the adjustment of high voltage and current according to the measured content. The target material of the X-ray tube has also been changed.
(3) A newly designed digital multichannel pulse amplitude analyzer using FPGA, DSP, and other technologies has replaced the original simple multichannel pulse amplitude analyzer, reducing dead time, increasing the counting rate, and also reducing weight and volume.
(4) The X-ray tube and high voltage have been integrated, reducing weight and volume.
(5) A new large-scale integrated circuit CPU has replaced the original small-scale circuit, and surface-mount technology has replaced the original vertical circuit. Lithium-ion batteries have replaced the switch power supply.
Improvements (1), (2), and (3) have reduced the background and increased sensitivity, thereby significantly lowering the detection limit to 2.6ppm (300s), making this sulfur analyzer fully capable of meeting the PLOQ (combined quantification limit) requirement of 16ppm in the 2019 version of GB/T17040. It also complies with the relevant requirements of the national standard GB17411 and the American national standard ASTM D4294. Improvements (3), (4), and (5) have greatly reduced the weight and volume of the sulfur analyzer.
The GA-1262 model EDXRF portable sulfur analyzer is a portable instrument. It is compact and lightweight, weighing only about 5kg (including battery and printer), making it easy to carry and suitable for on-site rapid detection and analysis without the need for gas, vacuum, or dilution.
The launch of the DM1262 model EDXRF portable sulfur analyzer is the result of our company's self-transcendence and will surely maintain our company's long-term leading position in the field of X-ray fluorescence analyzers.

ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence EDXRF X-ray Fluorescence Spectrometer Sulphur Testing 

Applicability

Particularly suitable for various institutions that require on-site rapid detection to measure the sulfur (S) element in various oil products (such as gasoline, diesel, marine diesel, fuel oil, and gasoline, fuel oil in circulation, etc.) with a measurement range from 16ppm to 10%.
Suitable for refineries, testing and certification institutions, oil depots, laboratories, etc., for measuring the sulfur (S) element in various oil products (such as gasoline, diesel, heavy oil, residual fuel oil, etc.), additives, lubricating oils with additives, and products in the refining process with a measurement range from 16ppm to 10%.
Also suitable for the measurement of the sulfur (S) element in any material across various industries.

ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence EDXRF X-ray Fluorescence Spectrometer Sulphur Testing 

Features
Fast and Accurate - The measurement time required is extremely short, typically giving content results within tens of seconds. It has high repeatability and reproducibility.
Low Detection Limit - Utilizing EDXRF technology with a low background thin beryllium window proportional counter and secondary filters achieves a lower detection limit.
Compact and Portable - Weighs only about 5kg (including battery and printer), suitable for atmospheric measurement without auxiliary equipment, especially suitable for on-site rapid detection.
Long Battery Life - With very low power consumption, using lithium-ion batteries allows for long periods of continuous use.
Strong Adaptability - Automatic C/H ratio correction, matrix effect correction, suitable for various samples. Automatic working curve switching, suitable for a wide measurement range.
Long-term Stability - Using a variable gain digital multichannel with PHA automatic adjustment and deviation correction functions, it has excellent long-term stability.
Eco-friendly and Energy-saving - Radiation protection meets exemption requirements. Analysis does not contact or destroy the sample, is pollution-free, does not require chemical reagents, nor does it require combustion.
Easy to Use - Touchscreen operation. Samples are directly placed into the sample cup, and after placing them into the instrument, just press the [Start] button to achieve one-touch operation.
High Reliability - Integrated design with a high degree of integration, strong environmental adaptability, strong anti-interference capability, and high reliability.
Data Storage and Transfer - Can store a large amount of data, supports data retention after power loss, and can be viewed at any time. Stored data can also be transferred to a PC.
High Cost Performance - No need for gas, vacuum, or dilution, with very low operating and maintenance costs. The price is half that of similar foreign products.

ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence EDXRF X-ray Fluorescence Spectrometer Sulphur Testing 
Calibration
The content is divided into three ranges: low (0-1000ppm), medium (0.1%-1%), and high (1%-4.6%). The instrument is calibrated within each range using five sulfur-containing samples with known content, resulting in working curves as shown in Figures 1, 2, and 3.
ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence Edxrf X-ray Fluorescence Spectrometer Sulphur Testing
Figure 1. Working Curve for Sulfurous Samples with Low (0-1000ppm) Content Range
ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence Edxrf X-ray Fluorescence Spectrometer Sulphur TestingFigure 2. Working Curve for Sulfurous Samples with Medium (0.1%-1%) Content Range

ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence Edxrf X-ray Fluorescence Spectrometer Sulphur TestingFigure 3. Working Curve for Sulfurous Samples with High (1%-4.6%) Content Range
 
All working curves have a correlation coefficient γ greater than 0.999, indicating that the linear error of the DM1262 is extremely small.

ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence EDXRF X-ray Fluorescence Spectrometer Sulphur Testing 
Repeatability (r):
The same operator, in the same laboratory, using the same DM1262 under the same conditions to measure the same sample, obtained two test results as shown in Table 1
ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence Edxrf X-ray Fluorescence Spectrometer Sulphur Testing
All test results have a reproducibility r that is less than the reproducibility r required by GB/T 17040, indicating that the DM1260 sulfur analyzer fully meets the reproducibility requirements of the 2019 version of GB/T 17040.

Repeatability (R):
Different operators, in different laboratories, using different DM1262 sulfur analyzers, measure the same sample, and the two test results obtained are shown in Table 2.
ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence Edxrf X-ray Fluorescence Spectrometer Sulphur Testing
All test results have a repeatability R that is less than the repeatability R required by GB/T 17040, indicating that the DM1262 fully complies with the repeatability requirements of the 2019 version of GB/T 17040.
 
 
ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence EDXRF X-ray Fluorescence Spectrometer Sulphur Testing 
Product Parameters

Main technical index

X-ray Tube Voltage: ≤10keV, Current: ≤1mA,Power: ≤10W
Detector Ultra-thin beryllium window proportional counter.
Detection Limits (300s) 2.6ppm
Measurement Range 3 times the detection limit to 9.99%
Linearity Error
Analytical precision
Meets GB/T 17040,GB 17411,ASTMD4294 and other related standards.
System Analysis Time 1~999 seconds, Recommended Values: 300 seconds or 600 seconds for trace measurement, 60 seconds for routine measurement
Operating Conditions Temperature -10ºC ~ 40ºC, relative humidity ≤95% (35ºC)
Power Supply 20.8Ah (Ampere-hours) and 11.1V (volts) built-in lithium-ion battery pack can operate for 5 hours in the measurement state.
Overall Power Consumption ≤50W
Dimensions and Weight 242mm (W)×258mm (D)×142mm (H), 5.6kg (including battery and printer)
ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence EDXRF X-ray Fluorescence Spectrometer Sulphur Testing 
Detailed Photos

ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence Edxrf X-ray Fluorescence Spectrometer Sulphur Testing

 

 

ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence Edxrf X-ray Fluorescence Spectrometer Sulphur TestingASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence Edxrf X-ray Fluorescence Spectrometer Sulphur Testing

 

 

 

 

 

Our Advantages

ASTM D4294 Portable Sulfur Analyzer Teser Testing Machine with Energy Dispersive X-ray Fluorescence Edxrf X-ray Fluorescence Spectrometer Sulphur Testing

 

 

 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier