GA-602 ASTM D5808-18 ASTM D5194 Microcoulometric Chlorine Analyzer

Product Details
Customization: Available
After-sales Service: online
Warranty: 1 year
Still deciding? Get samples of US$ 4000/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (7)
  • GA-602 ASTM D5808-18 ASTM D5194 Microcoulometric Chlorine Analyzer
  • GA-602 ASTM D5808-18 ASTM D5194 Microcoulometric Chlorine Analyzer
  • GA-602 ASTM D5808-18 ASTM D5194 Microcoulometric Chlorine Analyzer
  • GA-602 ASTM D5808-18 ASTM D5194 Microcoulometric Chlorine Analyzer
  • GA-602 ASTM D5808-18 ASTM D5194 Microcoulometric Chlorine Analyzer
  • GA-602 ASTM D5808-18 ASTM D5194 Microcoulometric Chlorine Analyzer
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Our Advantages
Overview

Basic Info.

Model NO.
GA-602
Transport Package
Plywood
Specification
81*40*41*(cm)
Trademark
GONOAVA
Origin
Changsha
HS Code
9024800000
Production Capacity
200

Product Description

Product Description

GA-602 ASTM D5808-18 ASTM D5194 Microcoulometric Chlorine Analyzer

IntroductionIntroduction 
The microcoulometric chlorine analyzer utilizes microcoulometric analysis technology and is a product of microcoulometric titration controlled by a computer. It features reliable performance, easy operation, good stability, and is convenient for installation. It is suitable for the determination of chlorine content in petrochemical products and is extensively applied in sectors like petroleum, chemical industry, and scientific research.
 

Features
  1. Compact structural design with an aesthetically pleasing appearance.
  2. Controlled by a computer with a color LCD display showing peak shapes.
  3. Automatic data processing and report printing output.
  4. High control precision with PID regulation (±1°C).
  5. Pyrolysis furnace with overheat protection, ensuring a long service life (over 3 years).
  6. The mixer is integrated with the main unit to prevent the quartz tube from breaking.
  7. The high-temperature furnace has a unique insulation and heat dissipation design, which is effective.
  8. Equipped with a self-check function to automatically determine whether it is a hardware failure or an analytical system issue.
  9. The experimental temperature of the pyrolysis furnace is set, controlled, and saved by the computer.
  10. Automation of bias adjustment; once the target bias is set, it adjusts automatically without supervision.
  11. The chlorine electrolytic cell is uniquely designed with solid silver rod electrodes, which do not require prior preparation. The independent reference electrode design facilitates replacement.
  12. The titration cell has a long stabilization time, and the electrolyte's lifespan is extended to over 24 hours after the sample gas is purified.
  13. The titration cell holds a 70% glacial acetic acid solution with a capacity of 50ml, allowing for analysis of samples over 24 hours without maintenance. It offers accurate measurements, short startup time, and low maintenance.
  14. The detector is equipped with an independent temperature control. The long stabilization time of the titration cell keeps the titration temperature constant. The gas after titration can be vented outside through a hose or passed into a distillation flask for adsorption.
GA-602 ASTM D5808-18 ASTM D5194 Microcoulometric Chlorine Analyzer
Product Parameters
 
Standard Number English Name
GB/T 264 Method for the determination of acid value of petroleum products
GB/T 7599-87 Method for the determination of acid value of transformer oil and turbine oil in service (BTB method)
GB/T 7304-2014 Method for the determination of acid value of petroleum products and lubricants
GB/T 18609-2011 Potentiometric titration method for the determination of acid value of crude oil
ASTM D664-2017 Standard Test Method for Acid Number Determination by Potentiometric Titration
   

Technical Parameter
 


Measurement Accuracy
Concentration (ppm) Sample Volume (µL) RSD (%)
0.2 ~ 1 10 30
1 ~ 10 10 10
10 ~ 100 5 3
>100 5 2
Gas Source Requirements  Normal nitrogen, normal oxygen
Power Supply AC 220V ± 22V, 50Hz ± 0.5Hz
Power 3.5KW
Temperature Control Range Room temperature ~ 1100°C
Temperature Control Accuracy ±1°C
Dimensions 860(L) x 440(W) x 380(H) mm
Weight 46Kg
GA-602 ASTM D5808-18 ASTM D5194 Microcoulometric Chlorine Analyzer
Detailed Photos

 GA-602 ASTM D5808-18 ASTM D5194 Microcoulometric Chlorine AnalyzerGA-602 ASTM D5808-18 ASTM D5194 Microcoulometric Chlorine AnalyzerGA-602 ASTM D5808-18 ASTM D5194 Microcoulometric Chlorine AnalyzerGA-602 ASTM D5808-18 ASTM D5194 Microcoulometric Chlorine AnalyzerGA-602 ASTM D5808-18 ASTM D5194 Microcoulometric Chlorine AnalyzerGA-602 ASTM D5808-18 ASTM D5194 Microcoulometric Chlorine Analyzer
 
Our Advantages
 




 

GA-602 ASTM D5808-18 ASTM D5194 Microcoulometric Chlorine Analyzer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier