  • High Precision Measurement: Accuracy up to 2% with resolution of 0.1mw/m k for low thermal conductivity materials.
  • Customizable Sample Size: Standard 50x50 to 300x300mm with special sizes available upon request.
  • Automatic Data Processing: Computer-controlled automatic testing, printing, and storage of experimental reports.
  • Versatile Material Testing: Suitable for plastic, rubber, aerogel, vacuum glass, and insulation materials.
  • Precision Pressure Control: Computer precision pressure clamping with 0-1000N range and 0.1N resolution.
  • 1-Year Warranty Coverage: Includes 1-year warranty with online after-sales service support.
  • Low MOQ Availability: Minimum Order Quantity is 1 piece with flexible payment terms.

Product Images of DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518

DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518 pictures & photos
DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518 pictures & photos
DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518 pictures & photos
DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518 pictures & photos
DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518 pictures & photos
DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518 pictures & photos
DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
  • DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
    DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
  • DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
    DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
  • DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
    DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
  • DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
    DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
  • DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
    DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
  • DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
    DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518

Find Similar Products

Product Description

DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
1.Product introduction

Using the international popular heat flow meter to detect thermal conductivity and thermal resistance method, with computer to achieve automatic detection, generate experimental report. The instrument uses a stable hot surface temperature added to the sample side, the heat is transferred to the cold surface through the sample, and the heat transfer is measured to calculate the thermal conductivity and thermal resistance. Using imported sensor and computer technology, good measurement accuracy, high reliability, good repeatability characteristics. Especially suitable for low thermal conductivity measurements (accurate to 0.1mw). Can be used for plastic, rubber, aerogel plate, vacuum glass, insulation materials and other testing, widely used in colleges and universities, scientific research institutes, quality inspection, factories and mines. Reference standard: GB/T10295-2008 (Determination of steady-state thermal resistance and related properties of insulating materials Heat flow meter method) and ASTM C518-04 test method for determination of steady-state heat flux and heat transfer characteristics by heat flow meter method
Product Parameters
DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
2. Product Parameter
thermal conductivity range
and accuracy

 
0.0001 ~ 3W/m k, can be measured accurately to 0.1mw/m k.
measurement accuracy
 
2%.
sample size
 
50×50 ~ 300×300 (mm). Special size can be customized.
 
hot surface temperature and control
 
room temperature ~ 500ºC, room temperature ~ 1000ºC, room temperature ~ 1350ºC optional, plate heater, bidirectional SCR control, temperature control accuracy 1ºC.
 
cold surface temperature
 and control
 
0 ~ 99.9ºC (standard configuration),-10 ~ 99.9ºC, according to user requirements to determine the lower temperature. The cold surface adopts water cooling to ensure the temperature stability of the cold surface (precision constant temperature sink, temperature adjustable), temperature control accuracy of 0.1ºC.
 
the sample adopts computer precision pressure clamping, pressure range 0 ~ 1000N, resolution 0.1N.
sample thickness automatic measurement, 0 ~ 50mm, resolution 1um.
imported heat flow meter, stable and reliable performance.
The whole process adopts the computer to automatically test and print and store experimental data.
Detailed Photos

DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518
DRPL-V high temperature/high precision material thermal conductivity tester plate heat flow meter ASTM C518

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASI249867". Items marked "verified" are certified.

Watch Video
Watch Video
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd
Hunan Gonoava Instrument Co Ltd

About Our Factory & Business Background

verified Business Type
Trading Company
Address
Room 2318, Building 29 Yingyuewan, Runhe Yicheng Yueliangdao Street, Wangcheng, Changsha, Hunan, China
verified Plant Area
120 square meters
verified Number of Employees
8
verified Terms of Payment
T/T, LC, D/P, PayPal, Small-amount payment, Western Union
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port
verified Minimum Order Quantity
1 Piece
verified Supply Chain Partners
9

Our Production Capability & Technical Expertise

verified Main Products
Differential Scanning Calorimeter; Gas Chromatograph; Vacuum Type Dilatometer; Tensile Strength Tester
verified Customization Options
Customization from Samples
verified R&D Engineers
1 people

Our Industry Experience & Global Business Record

verified Year of Establishment
2023-04-06
verified Export Year
1 Year
verified Main Markets
North America, Southeast Asia/ Mideast, East Asia(Japan/ South Korea)
verified Repeat Buyers Choice
< 10%
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
No

Our Certifications, Standards & Industry Recognition

verified Cooperated with Fortune 500
No

FAQ

What is the measurement accuracy of the device?
The device offers a measurement accuracy of 2% and can measure accurately to 0.1mw/m k.
Can the sample size be customized?
Yes, special sizes can be customized beyond the standard range of 50x50 to 300x300mm.
What is the minimum order quantity?
The minimum order quantity is 1 piece.
What is the lead time for delivery?
The lead time is within 15 workdays for both peak and off-peak seasons.
What payment methods are accepted?
Accepted payment terms include T/T, LC, D/P, PayPal, Small-amount payment, and Western Union.
Does the product come with a warranty?
Yes, the product includes a 1-year warranty with online after-sales service.
What standards does the tester comply with?
It complies with GB/T10295-2008 and ASTM C518-04 test methods.