• LCD Touch Screen Dta Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment Ga-1901-B
  • LCD Touch Screen Dta Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment Ga-1901-B
  • LCD Touch Screen Dta Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment Ga-1901-B
  • LCD Touch Screen Dta Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment Ga-1901-B
  • LCD Touch Screen Dta Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment Ga-1901-B
  • LCD Touch Screen Dta Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment Ga-1901-B

LCD Touch Screen Dta Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment Ga-1901-B

After-sales Service: Online
Warranty: 1 Year
Type: Differential Thermal Scanning Analyzer
Weight: 30kg
Power Source: AC220V
Display Mode: 7 Inch LCD Touch Screen Display
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2024

Suppliers with verified business licenses

Hunan, China
Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (6)

Basic Info.

Model NO.
GA-1901-B
Transport Package
Plywood Case
Specification
33*20*40cm
Trademark
GONOAVA
Origin
China
HS Code
9024800000
Production Capacity
200

Product Description

LCD Touch Screen DTA Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment GA-1901-B
Product Introduction
Differential thermal analysis (DTA) is a technique to measure the temperature difference and temperature relationship between a substance and its reference substance under programmed temperature control. The dTA curve describes the temperature (△T) between the sample and the reference as a function of temperature or time. In DTA tests, sample temperature changes are caused by endothermic or exothermic effects of phase transitions or reactions. Such as: phase transformation, melting, crystal structure transformation, boiling, sublimation, evaporation, dehydrogenation, fracture or decomposition reactions, oxidation or reduction reactions, lattice structure destruction and other chemical reactions.

Instrument features:
1. The main control chip of the instrument adopts Cortex-M3 core ARM controller, with faster processing speed and better temperature control.
2. USB two-way communication, more convenient operation.
3. Adopt 7 inch 24bit full-color LCD touch screen, more friendly interface.
4. Platinum rhodium alloy sensor, more high temperature resistance, corrosion resistance, oxidation resistance.

LCD Touch Screen DTA Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment GA-1901-B
Technical parameters:
1. Temperature range: room temperature ~1450ºC
2. Range: 0 ~ ±2000μV
3. DTA accuracy: 0.01μV
4. Heating rate: 0.1 ~ 100ºC/min
5 temperature resolution: 0.01ºC
6 temperature accuracy: ±0.1ºC
7. Temperature repeatability: ±0.1ºC
8. Temperature control: heating up: program control can be adjusted according to the needs of the parameters
Constant temperature: program control constant temperature time arbitrary setting
9. Furnace body structure: the furnace body adopts the upper cover structure, instead of the traditional lifting furnace body, high precision, easy to operate
10. Atmosphere control: internal program automatically switch
11. Data interface: standard USB interface with data cable and operating software
12. Display mode: 24bit color, 7 inch LCD touch screen display
13. Parameter standard: equipped with standard materials, with a key calibration function, users can calibrate the temperature by themselves
14. Baseline adjustment: Users can adjust the baseline based on the slope and intercept of the baseline
15. Working power supply: AC 220V 50Hz (other specifications can be customized)

LCD Touch Screen DTA Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment GA-1901-B
Test map: glass transition temperature
LCD Touch Screen Dta Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment Ga-1901-B
Aggregate peak information:
Enthalpy 60.2686 j/g .  Peak 238.5 c.   beginning 232.7c .  End point244.1c

LCD Touch Screen Dta Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment Ga-1901-BLCD Touch Screen Dta Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment Ga-1901-BLCD Touch Screen Dta Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment Ga-1901-BLCD Touch Screen Dta Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment Ga-1901-BLCD Touch Screen Dta Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment Ga-1901-BLCD Touch Screen Dta Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment Ga-1901-B

LCD Touch Screen Dta Differential Thermal Scanning Analyzer Apparatus Thermal Testing Equipment Ga-1901-B
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now