• Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L
  • Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L
  • Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L
  • Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L
  • Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L
  • Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L

Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L

After-sales Service: Online
Warranty: 1 Year
Weight: 170kg
Transport Package: Plywood Case
Specification: 900*760*920mm
Trademark: GONOAVA
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2024

Suppliers with verified business licenses

Hunan, China
Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (6)

Basic Info.

Model NO.
GA-2001-A
Origin
China
HS Code
9024800000
Production Capacity
200

Product Description

GA-2001-A Programmable Temperature Humidity Chamber Testing Box Equipment for Climate simulation Tests 36L 
1. Function 

It simulates the products in the chamber where the climate condition of different temperature and humidity, such as high-low operation and storage, temperature cycling, high-low temperature and high-low humidity, moisture condensation etc. to check its adaptability and changing performance. 
It's required to conform to international regulation (IEC, JIS, GB, MIL…) to reach the consistency (including test schedule, condition, method) under the international standard. 

2.Design Standard:
GB11158 High Temperature Test Chamber Technical Condition
GB10589-89 Low Temperature Test Chamber Technical Condition
GB10592-89 High-low Temperature Test Chamber Technical Condition
GB/T10586-89 Damp Heat Test Chamber Technical Condition
GB/T2423. 1-20 Low Temperature Test Chamber Test Methods
GB/T2423.2-20 High Temperature Test Chamber Test Methods
GB/T2423.3-93 Damp Heat Test Chamber Test Methods
GB/T2423.4-93 Alternating Damp-Heat Test Methods
GB/T2423.22-2 Temperature Changing Test Methods
IEC60068-2- 1. Low Temperature Test Chamber Test Methods
IEC60068-2-2. High Temperature Test Chamber Test Methods
GJB150.3 High Temperature Test Methods
GJB150.4 Low Temperature Test Methods
GJB150.9 Damp Heat Test Methods

GA-2001-A Programmable Temperature Humidity Chamber Testing Box Equipment for Climate simulation Tests 36L 
3.
Uses

This equipment can simulate different environment condition. It's appropriate for testing material
performance, such as resist heat, resist dry,resist humidity and resist cold. That can define performance of
material.

4. Sample application 
The chamber applies to: 
compatibility test for store, transportation and application of 
electric, electronic products, unit components, parts and other 
materials under high or low temperature. 
The following samples are prohibited to be tested and stored: 
- Inflammable , explosive and other volatile substances; 
- Corrosive substance; 
- Biont; 
- Strong electromagnetic emission source. 

GA-2001-A Programmable Temperature Humidity Chamber Testing Box Equipment for Climate simulation Tests 36L 
5. Volume, size & weight
 
5.1. Volume:36L 
5.2. Internal size:W 350 x H300 x D350mm 
5.3. Exterior size;W900 x H760 x D920mm
5.4. Weight:170KG 

6. Performance 
6.1. Test condition 
Temperature:+25ºC, Humidity: ≤85%, no samples in the chamber 
6.2. Test method 
GB/T 5170.2-1996 Temperature test chamber 
GB/T5170.5-1996 Temperature and humidity test chamber (only 
temperature and humidity) 
6.3. Temperature range:-20ºC→+150ºC (adjustable)
6.4. Temperature fluctuation:±0.5ºC 
6.5. Temperature accuracy distribution:±2.0ºC 
6.6. Humidity range:30%~98%R.H (temperature at 20ºC-85ºC) 
6.7. Humid. fluctuation:±2.5%R.H. 
6.8. Humidity accuracy distribution:±3.0%. 
6.9. Heat-up time:-20ºC → +150ºC Heat up for 2-4.0ºC/min 
6.10. Cooling time: +150ºC→ -20ºC Cooling for 0.7-1.0ºC/min 
6.11. Load condition:Testing space is not more than 3/4 of the total space, no heating 
6.12. Sample holder:Stainless steel punching stencil
6.13. Relative humidity and temperature control range (refer to fig.) 
Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L
6.14. Meet the technical standards:
GB/T 2423.1-2001 Test A: Low temperature test method 
GB/T 2423.2-2001 Test B: High temperature test method 
GJB 150.3-1986 High temperature test 
GJB 150.4-1986 Low temperature test 
IEC68-2-1 Test A: Cold 
IEC68-2-2 Test B: Dry heat 
GB11158 "Technical Conditions for High Temperature Test Chamber " 
GB10586-1 "Technical conditions for Damp heat test chamber " 
GB/T 2423.2 "Basic environmental testing procedures for electric and electronic products B: High temperature test method". 
GB/T 2423.3 "Basic environmental testing procedures for electric and electronic products Ca: Constant damp heat testing method" etc

GA-2001-A Programmable Temperature Humidity Chamber Testing Box Equipment for Climate simulation Tests 36L 
7. Structure characteristics.
 
7.1. Insulated enclosure structure: 
External material: SUS304 or stoving varnish 
Inwall material: SUS304 
Insulation material of box body: flame retardant fire rigid 
polyurethane foam 
Door thermal insulation material: flame retardant fire rigid 
polyurethane foam 
7.2. Air conditioning channel: 
Centrifugal fan,Heater, evaporimeter, outfall, temperature sensor
7.3. Test chamber standard: 
Window 330x450x40mm 3 vacuum layers 
Anti-explosion handle 
Door hinge: SUS #304 
Lamps in the chamber: 11W 
Access port: φ50mm or φ100mm 1pc or more. 
7.4. Door 
Single door, open from left, handle is at right; With viewing window: 
W300xH450mm, lamp window/condensation prevention thermal device 
7.5. Controller 
Control screen, overtemperature protection setting 
7.6. machine room 
Refrigeration units , water pans , outfall 
7.7. control cabinet for power distribution 
Switchboard fan, ventilator 
7.8. Heater 
Heating system: cycling heating from finned-tube Stainless steel electric heater 
7.9. Humidifier 
Oven humidification system, cycling winding system 
7.10. Power line hole and 
outfall position located at the back of chamber 

8. Cooling system (Binary cascade refrigeration)
8.1. Cooling compressor 
Tecumseh (France) 
Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L
8.3. Evaporator 
fins-tube evaporator
 Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L
8.4. Condensator 
Air-coolled tube-type condensator 
Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L
8.5 Expansion system 
Refrigeration system of volume control (capillary)
8.6 Evaporative condenser 
Stainless steel brazing plate-type heat exchanger 
Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L
8.7 Chiller control 
Operation of cooling machine can be adjusted automatically by control system according to the test condition 
evaporating pressure adjustable valve 
Cooling loop of compressor 
8.8 Freezing medium 
R404a (Eco-friendly, Ozone loss rate at 0) 
Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L
9 Controller 
Independent R&D software (Taiwan) 
Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L
9.1 Temperature and Humidity controller 
Imported 7.0 inch LCD touch screen control, programmable of temperature and humidity; 100 groups of program and 1000 groups of memory, each for 99hrs 59min and can be set as required with groups of PID control function. 
9.2 Controller specifications 
Precision: Temp. ±0.1ºC+1digi, humid.: ±1%R.H+1digit 
Distinguishability: Temp.: ±0.01ºC, humid.:±0.1%R.H. 
slope temperature; 0.1~9.9 adjustable. 
With warning function and up& down limitation standby 9 groups of PID control parameters and PID auto-calculation. Dry and damp ball with auto correction.
9.3 Function of page display, 
program volume and control function 
- Touch screen operation, no need to input by key pressing; 
- Temp. and Humid. Set (SV) with true (PV) value shown. 
- Display of current program No., phase, time left and cycling times. 
- Run the operation of accumulative time. 
- Program set value of Temp.& humid. shown as curve; 
- At least 5 phase of temp. & humid, time can be input on the sole program editing page. 
- Language can be switched between English and Chinese; 
- Fault page shown; 
- Back light adjustable of screen; 
- Protection function can be set by time, TIMER can be turn off by manual; 
- Program groups available: 100 max. PATTEN. 
- Memory volume available: 1000 SEGMENTS. 
- Repeat executive command: up to 90 times for each command. 
- Program with editing, cancel and insert available; 
- Time set of SEGMENTS: 0~90Hour59Min; 
- Module device controlled by program; 
- Electricity cut memory, with auto start-up and executive program function after switch on; 
- program execution with display of curve diagram; 
- With auto adjustable freeze function; 
- Reservation of start-up and turn-off available; 
- Data and time adjustable; 
- Key-pressing and page lock (LOCK) available. 

10 Safety protection device
a) Cooling system 
- compressor overheated 
- compressor overflowed 
- compressor overpressed 
- condensate fan overheated 
- oil pressure protection of compressor 
b) Test chamber 
Adjustable overheat 
Air conditioning channel overtemperature limit 
Wind motor overheated 
c) Other 
- phase sequence and open phase protection of main power supply 
- leakage protection 
- heating, humidification and Dry burning-resistant protection 
- overload and short circuit protection 
- overtemperature outage protection

11 Other equipped parts 
a) power control contactor of sample testing 
Contactor of relay control: within AC220V, 2A (contactor closed under normal running, when chamber stops or of malfunction, contactor open). 
b) leakage breaker of 
main power supply:AC220V, 50Hz+Grounding wire. 

12 Accessories 
a) Power (Standard) 
Five core single-phase three-wire and 1piece of protection grounding wire (optional) 
b) Access port 
φ50mm, φ80mm, φ100mm, φ120mm available according to your 
requirement and cab be customized on the premise that not affect 
the machine performance
c) USB interface (Standard) 
All the history curve and history data can be downloaded from 
controller as Excel or JPG according to date. 
d) Remote Control System (optional) 
Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L
13 Transportation 
The chamber as a unitary to be transported 
a) Delivery size:Max. size (package not included): refer to "exterior size" 
b) Weight:Max. delivery weight (package not included): refer to "Weight" 

14 Usage requirements 
Assured by users as below requirements 
14.1 Installation position 
- With leveling ground and good ventilation; 
- No strong shock near the chamber; 
- No strong electromagnetic field near the chamber 
- No inflammable , explosive , corrosive material and dust 
- Surrounding size for chamber operation and maintenance: 
A: not less than 10cm 
B: not less than 60cm 
C: not less than 60cm 
D: 225 type: not less than 80cm 
408 type: not less than 90cm 
1000 type: not less than 120cm 
14.2 Condition 
Temperature: 5ºC~30ºC 
Humidity: ≤85% 
Air pressure: 86kPa~106kPa 
14.3 Tap water: only for damp heating equipment with pure water machine 
Water flow ≥200kg/h, pressure: 0.1Mpa ~ 0.25Mpa. 
Tap water conforms to GB 5749-1985 drinking water standard; 
Remark: equipped with DN15 male adapter of pure water machine
14.4 Power supply condition 
- AC220V + Protection grounding 
- Voltage fluctuation range: AC(220±10%) V 
- Frequency fluctuation range: (50±0.5)Hz 
- Resistance of protection grounding wire less than 4Ω. 
- It's required to equipped with air or motive switch of corresponding capacities, which is also used only for the chamber 
Total power:3.8 KW 
Max. Current:16A 
Voltage:220V 
 
 
Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L
Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L
Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L


Ga-2001-a Programmable Temperature Humidity Chamber Testing Box Equipment for Climate Simulation Tests 36L

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now