  • GA-601 ASTM D5453 ISO 20846 UV Fluorescence Sulfur Analyzer
  • GA-601 ASTM D5453 ISO 20846 UV Fluorescence Sulfur Analyzer
  • GA-601 ASTM D5453 ISO 20846 UV Fluorescence Sulfur Analyzer
  • GA-601 ASTM D5453 ISO 20846 UV Fluorescence Sulfur Analyzer
  • GA-601 ASTM D5453 ISO 20846 UV Fluorescence Sulfur Analyzer
  • GA-601 ASTM D5453 ISO 20846 UV Fluorescence Sulfur Analyzer
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Our Advantages
Overview

Basic Info.

Model NO.
GA-601
Transport Package
Plywood
Specification
120*110*150*(cm)
Trademark
GONOAVA
Origin
Changsha
HS Code
9024800000
Production Capacity
200

Product Description

Product Description

GA-601 ASTM D5453 ISO 20846 UV Fluorescence Sulfur Analyzer

Introduction
UV Fluorescence Sulfur Analyzer uses the UV fluorescence method to determine the total sulfur content, enhancing its ability to resist interference from impurities and avoiding the cumbersome operations and instability associated with the titration cell in the coulometric method, which greatly improves the instrument's sensitivity. Key components of the system are made with imported devices, preventing light and gas leaks, ensuring reliable performance of the entire machine.

Advantages of the GA-601 UV Fluorescence Sulfur Analyzer
Features

  • The instrument's performance is continuously improved and enhanced, with an aesthetically pleasing appearance and a rational structure.
  • An optional built-in electronic mass flowmeter is available, with gas flow controlled automatically by the operating software, fully automatic program monitoring, and clear digital display.
  • The instrument is equipped with an automatic function for gas pressure abnormalities.
  • Digital display of gas flow and pressure throughout the process.
  • The computer controls the sampler for automatic sampling, eliminating the need for manual operation.
  • The operation interface and print format can be customized according to user requirements.
  • The computer controls the entire analysis and data processing process, displaying the working status of the entire process.
  • The uniquely designed fluorescence chamber has an automatic compensation function for the intensity of the ultraviolet light source, offering high sensitivity and low baseline noise.
  • It includes a selective permeation membrane aromatic hydrocarbon barrier filter system, ensuring the detection system cannot be contaminated.
  • Special quartz pyrolysis tubes are used, which do not require disassembly or replacement, addressing the issue of carbon buildup in combustion tubes.
  • The instrument is equipped with a gas filtration and purification system.
  • Key components are imported, reducing instrument noise and increasing detection sensitivity.
GA-601 ASTM D5453 ISO 20846 UV Fluorescence Sulfur Analyzer
Product Parameters
 
Technical Specifications Details
Sample Types Liquid, Solid, and Gas
Measurement Method UV Fluorescence (S)

Sample Injection Volume
Solid Sample: 1-90mg
Liquid Sample: 2-50μL
Gas Sample: 1-50mL
Measurement Range 0.01 to 20000 ppm (mg/L) to % (High concentrations can be diluted)
Measurement Precision
Concentration (ppm) RSD (%)
0.1~1 10
1~100 5
100~10000 2.5
Temperature Control Range Room temperature to 1300°C
Temperature Control Accuracy ±1°C
Sample Detection Time Approximately 2 minutes
Gas Source Requirements Gas Source Requirements
Oxygen: Purity above 99.9%
Power Supply AC220V±22V, 50Hz±0.5Hz, 1500W
Dimensions 510(W) x 490(D) x 535(H) mm
Weight Over 50kg

System Configuration Table
System Configuration Details
Standard Configuration Computer + GCTS-6000 System + Liquid Sampler
Other Options Solid Sampler, Gas Sampler, Mass Flow Meter

Key Components Table
Key Component Details
Membrane Dryer Imported
UV Lamp Imported
Photomultiplier Imported
214 Filter Imported
 
 
GA-601 ASTM D5453 ISO 20846 UV Fluorescence Sulfur Analyzer
Detailed Photos

GA-601 ASTM D5453 ISO 20846 UV Fluorescence Sulfur AnalyzerGA-601 ASTM D5453 ISO 20846 UV Fluorescence Sulfur AnalyzerGA-601 ASTM D5453 ISO 20846 UV Fluorescence Sulfur AnalyzerGA-601 ASTM D5453 ISO 20846 UV Fluorescence Sulfur AnalyzerGA-601 ASTM D5453 ISO 20846 UV Fluorescence Sulfur AnalyzerGA-601 ASTM D5453 ISO 20846 UV Fluorescence Sulfur Analyzer 
Our Advantages
 




 

GA-601 ASTM D5453 ISO 20846 UV Fluorescence Sulfur Analyzer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier