The basic working principle of gas chromatography technology: Gas, liquid or solid samples are sent into the chromatographic (separation) column system through a certain injection method through the vaporization chamber. The mixture components in the sample flow through the chromatographic column driven by the carrier gas (N2). Each component in the sample is separated under the action of the stationary phase in the chromatographic column. The chemical components are converted into electrical signals (current or voltage) proportional to their concentration in the detector. The electrical signals of the corresponding components are sent to the recording instrument or data acquisition and processing system, and the qualitative and quantitative analysis of the components in the mixture can be carried out.
BGD 266 Gas chromatograph Gas sulfide analysis test machine
2.Main performance features
Economic and practical, cost-effective
Unit overall structure design, easy to install and maintenance
Can be connected to chromatographic data workstation, greatly improve the work efficiency
Provide hydrogen flame ionization detector (FID) - high sensitivity analysis of organic compounds, suitable for printing solvent residue and solvent composition detection.
Capillary column injection port design
Large column box (300×300×200mm) : accurate completion of complex analysis tasks, the use of capillary column.
Advanced noise suppression system, in the chromatographic working state, completely eliminate fan noise, give you a quiet, comfortable working environment.
The injection device is all vitrified, and there are two ways of rapid vaporization and stigmatic injection.
New pressure stabilizer, a variety of air path system: the form of double air path, new pressure stabilizer system to ensure the reproducibility of the instrument
Microcomputer control, man-machine dialogue, easy operation
Advanced temperature control system, the use of microcomputer control, man-machine dialogue to draw a variety of required temperature column box temperature
Overheat protection function: can set any temperature within 400°C, software program protection, hardware circuit double insurance design.
Use chromatographic workstation to process data, analysis data can be stored in large quantities, and provide special analysis methods.
Temperature control range: RT+10°C ~ 400°C, 8-step temperature program Temperature rise speed: 0-30 °C/min (increment 0.1°C/min), temperature control accuracy is 0.1% Temperature control accuracy: ≤0.1ºC Main accessories or optional accessories: Hydrogen flame detector (FID) Detection limit: Mt≤1×10-11g/s (cetylane), baseline drift ≤1×10-12A/0.5h, noise ≤1×10-13A Thermal conductivity detector (TCD) Sensitivity: S≥2500mv.ml/mg (benzene), baseline drift ≤60μV/0.5h, noise ≤10μV Electron capture detector (ECD) Detection limit: M≤2×10-13g/ml (r-666) Flame photometric detector (FPD) Detection limit: Ms≤5×10-11g/s (thiophene), Mp≤1×10-11g/s (ethyl-1605) Nitrogen and Phosphorus detector (NPD) Detection limit: Mn: 1×10-13g/s, Mp: 1×10-13g/s (ethyl-1605) Detectable substances: benzene, cyclohexanone, xylene, ethanol, ethylbenzene, isopropanol, propanol, butanol, ethyl acetate, isopropanol acetate, n-butanol, toluene, N-butyl acetate, aniline phosphorus, 4-methyl 2-pentanone, etc Standard configuration: a host machine, a hydrogen flame detector, a column, a data workstation, a set of professional software, a set of installation accessories, a set of injectors, 50 sets of headspace bottles, sealing. Dimensions (length × width × height) : 500mm×43mm0×440mm Net weight: 50KG |