Differential Scanning Calorimeter High Precision Differential Scanning Calorimeter (DSC) for Glass Transition/Melting Point Test

Product Specifications Select Now
model number
GA-480D
Product Details
Customization: Available
After-sales Service: Online
Warranty: 1 year
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Online Trading Protection
Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.
Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (7)
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Our Advantages
  • Company Profile
  • Exhibition
  • Certifications
  • Packing & Delivery
  • FAQ
Overview

Basic Info.

Model NO.
GA-480D
Type
Differential Scanning Calorimeter
brand name
GONOAVA
Selling Units
Single item
Voltage
220V Electrical Equipment, Other
customized support
OEM, ODM, OBM, Software Reengineering
Accuracy Class
High Accuracy
place of origin
Hunan, China
power
Electronic
customizedsupport
OEM.ODM, OBMSoftware Reengineering
Trademark
GONOAVA
Origin
China
HS Code
9024800000
Production Capacity
200

Product Description

Product Description

Differential Scanning Calorimeter High Precision Differential Scanning Calorimeter (DSC) for Glass Transition/Melting Point Test

Product Introduction:
The GA-480D is a high-precision differential scanning calorimeter launched by our company. It uses an imported E-type thermocouple sensor, offering high accuracy, high sensitivity, and excellent repeatability. The signal acquisition circuit features shielding protection for strong anti-interference capabilities, resulting in extremely stable and repeatable baselines. The GA-480D differential scanning calorimeter can perform tests for glass transition temperature, phase transition temperature, melting point, enthalpy value, curing temperature, product stability, specific heat capacity, crystallization, and oxidation induction period. It is suitable for research in numerous fields, including pipes, polymers, chemicals, food, and medical applications. The product serves universities, enterprises, research institutes, and quality inspection agencies, with a very wide range of applications to meet the testing needs of various industries.

High Sensitivity DSC Analyzer with Touch Screen Differential Scanning Calorimeter for Polymer/Plastic/Food Thermal Analysis
Technical Features:
1. Industrial-grade 7-inch touchscreen with rich information display.
2. Brand new furnace structure for better baseline and higher accuracy. Heating uses an indirect conduction method, providing high uniformity and stability, and reducing pulse radiation, superior to traditional heating methods.
3. USB communication interface mode for strong versatility and reliable, uninterrupted communication, supporting automatic connection recovery.
4. Automatic switching of two gas flow channels with fast switching speed and short stabilization time. An additional protective gas input is also included.
5. Rich software functions, including a corresponding test case database. 6. Ultra-high sensitivity and accuracy, 0.001 mW

Differential Scanning Calorimeter High Precision Differential Scanning Calorimeter (DSC) for Glass Transition/Melting Point Test
Compliant with standards:
GB/T 33466.1-2016 Rigid polyvinyl chloride pipes - Differential scanning calorimetry (DSC) - Part 1: Measurement of processing temperature GB/T 40271-2021 Test methods for identification of textile fibers - Differential scanning calorimetry GB/T 19466.1-2004 Plastics - Differential scanning calorimetry (DSC) - General principles GB/T 19466.4-2016 Plastics - Differential scanning calorimetry (DSC) - Part 4: Determination of specific heat capacity GB/T 19466.5-2022 Plastics - Differential scanning calorimetry (DSC) - Part 5: Determination of characteristic reaction curve temperature, time, reaction enthalpy and conversion rate GB/T 19466.6-2009 Plastics - Differential scanning calorimetry (DSC) - Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) GB/T 19466.2-2004 Plastics - Differential scanning calorimetry (DSC) - Part 2: Determination of glass transition temperature GB/T 19466.3-2004 Plastics - Differential scanning calorimetry (DSC) - Part 3: Determination of melting and crystallization temperatures and enthalpies GB/T 29611-2013 Raw rubber - Determination of glass transition temperature (Partial national standards shown)
 
High Sensitivity DSC Analyzer with Touch Screen Differential Scanning Calorimeter for Polymer/Plastic/Food Thermal AnalysisDifferential Scanning Calorimeter High Precision Differential Scanning Calorimeter (DSC) for Glass Transition/Melting Point Test
Differential Scanning Calorimeter High Precision Differential Scanning Calorimeter (DSC) for Glass Transition/Melting Point Test
Differential Scanning Calorimeter High Precision Differential Scanning Calorimeter (DSC) for Glass Transition/Melting Point Test
Differential Scanning Calorimeter High Precision Differential Scanning Calorimeter (DSC) for Glass Transition/Melting Point Test
Specification
Temperature range
RT-600
DSC range
±1000mw
Temperature sensitivity
0.001
Heating rate
0.1~100/min
Cooling rate
1~20/min(550~100
DSC sensitivity
0.001mw
Data acquisition frequency
The software allows setting different sampling frequencies.
Temperature control method
It features intelligent PID temperature control, intelligent memory temperature control mode, and temperature accuracy that
combines the advantages of dynamic and static algorithms, with self-tuning and self-optimization functions.
Cooling method
Air-cooled
Flow meter
Mass flow meter, measuring range 0~200 ml/min (accuracy 0.1 ml/min)
Enthalpy accuracy
±0.5%
Atmosphere control system
Built-in two gas channels, compatible with nitrogen, oxygen, air, carbon dioxide, argon, etc.
Sensor type
E-type
Sensor technology
Thermal diffusion process
Furnace technology
Corrosion and oxidation resistant treatment
Operating software
The software can export data in formats such as Excel and PDF; it includes an automatic analysis function that can analyze
specific heat capacity, enthalpy, melting point, glass transition temperature, degree of curing, crystallization, and oxidation
induction time; the software has a database of standard testing methods; and it can compare more than 10 sets of data
simultaneously.
Program settings
≥50 segments, expandable
Comparison function
Standard sample comparison can be performed, and reasonable error values can be set; if the error value is exceeded, the
comparison will indicate a failure.
Our Advantages
Differential Scanning Calorimeter High Precision Differential Scanning Calorimeter (DSC) for Glass Transition/Melting Point Test
 
Company Profile
Differential Scanning Calorimeter High Precision Differential Scanning Calorimeter (DSC) for Glass Transition/Melting Point Test
HUNAN GONOAVA INSTRUMENT CO LTD Professionally supply kinds of testing machines for different industries,it is a collection development,research,production and sales of high accuracy testing machines,products meet UL,ASTM,JIS,ISO,GB,TAPPI,IEC,EN,DIN BS and other domestic and international standards.Provide customers with better overall laboratory solution,including lab design,machine customize and drawing, instrument selection,installation, training,maintenance,become one stop for testing instrument and machines. We have many years export experience,products are exported more than 50 countries,welcome abroad instruments dealer to become our sales agent.Our products is widly used in many industries,such as metal,gold,Ore,Raw material,plastic,packaging,paint,printing ink,leather,shoes,fabric,keyboard,Electronic product,auto and motorcycle ,Toys, mobile phone computer ,Sports equipment,Electroplating industry.
Differential Scanning Calorimeter High Precision Differential Scanning Calorimeter (DSC) for Glass Transition/Melting Point Test
Exhibition
Differential Scanning Calorimeter High Precision Differential Scanning Calorimeter (DSC) for Glass Transition/Melting Point Test
Certifications
Differential Scanning Calorimeter High Precision Differential Scanning Calorimeter (DSC) for Glass Transition/Melting Point Test
Differential Scanning Calorimeter High Precision Differential Scanning Calorimeter (DSC) for Glass Transition/Melting Point Test
Packing & Delivery
Differential Scanning Calorimeter High Precision Differential Scanning Calorimeter (DSC) for Glass Transition/Melting Point Test
FAQ
Q: How to buy your products ?
A: We have some products in stock , you can take away the products after you arrange the payment ; If we don't have the products in stock you want, we will start production once getting the payment.

 
Q: What's the warranty for the products ?
A: The free warranty is one year from the date of commissioning qualified.

 
Q: Can we visit your factory ?
A: Of course, welcome to visit our factory if you come to China.

 
Q: How long is the validity of quotation ?
A: Generally, our price is valid within one month from the date of quotation. The price will be adjusted appropriately as the price fluctuation of raw material in the market.

 
Q: What's the production date after we confirm the order ?
A: This depends on the quantity. Normally, for the mass production, we need about one week to finish the production.
Differential Scanning Calorimeter High Precision Differential Scanning Calorimeter (DSC) for Glass Transition/Melting Point Test

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now
People who viewed this also viewed