| Main Parameters: 1. Power Supply Voltage: Three-Phase AC 220V ±10% 2. Power Consumption: ≤5KW 3. Power Consumption: ≤5KW 4. Timer: Adjustable from 0 to 99.99 seconds/meter/hour 5. Timing Accuracy: <1 second/hour 6. Heat Flow Meter: 25.4mm diameter (0-5.7) Kw/m² 7. Heat Flow Meter Accuracy: ±0.2 Kw/m²; 8. Heat flow meter accuracy: <±3%; 9. There are two types of radiant panels: Propane gas panel: Made of porous refractory board with a SUS304 stainless steel shell, dimensions are 305±3mm*457±3mm; Radiant panel: High temperature resistance ≤ 900°C Electric heating panel: Made of six 76mm wide radiant strips with a SUS304 stainless steel shell, dimensions are 327±3mm*470±3mm. Radiant panel: High temperature resistance ≤ 900°C 10. Radiant panel gas source: Air + propane mixture 11. Radiant panel power supply: Three-phase 220V 12. Thermocouple: K-type stainless steel armored thermocouple, 0.5mm diameter 13. Gas flow meter: Accuracy ±1% 14. Air flow meter: Gas flow meter: Accuracy ±1% 15. Burner torch: Made of brass, flame aperture 0.15, length 71mm 16. Flame height: Adjustable to 127mm 17. Ignition system: High-voltage electronic ignition 18. Flue gas treatment system: Utilizes a powerful exhaust system. This unit is equipped with a powerful exhaust fan. After the test is completed, the exhaust fan system is activated to discharge the exhaust gas outdoors for purification and to meet national emission standards. |